Radiology & Imaging AI
M

mediaire

mediaire, a Berlin company founded in 2018, sells the md suite, MRI analysis software that radiology practices and hospital departments install on their own network. Studies are pulled from the scanner or PACS automatically or with one click, and measurements, overlays and a structured report go back to PACS in three to five minutes. Patient data never leaves the site.

mdbrain, the lead product, covers brain volumetry for dementia, multiple sclerosis and atypical parkinsonism, lesion characterization for MS and dementia, saccular aneurysm detection on time of flight angiography and tumor differentiation between glioma, metastasis and meningioma, each with longitudinal comparison against prior scans. mdprostate segments the prostate, measures its volume and, in Europe, maps suspicious lesions to PI RADS 2.1 with editable reports and contour export for fusion biopsy. mdknee grades cartilage damage to ICRS criteria. The software reads DICOM from Siemens, Philips, GE and Canon scanners at 1.5 or 3 tesla.

mediaire reports use in more than 400 imaging centers and 43 published clinical studies behind mdbrain. In a real life evaluation across five sites, median reading time fell 25% with mdbrain, 57% for dementia and 13% for MS. Spedali Civili Brescia, DIE RADIOLOGIE Munich and Ihre Radiologie Berlin are users, and Sectra, Incepto and Mint Medical distribute or connect the modules. FDA cleared mdprostate segmentation and volume under K252571 in August 2026. Billing is per examination volume plus installation and monthly service fees.

AI Health Index verifiedNovember 21, 2026
Compare mediaire with other vendors
Founded
2018
Headquarters
Berlin, Germany
Website
mediaire.ai/en/
Categories
radiology-and-imaging-ai
Indexed Products
md-suite, mdbrain, mdprostate, mdknee
Buyer Segments
Hospital radiology departments, Neuroradiology and prostate MRI teams, Independent imaging centers
Assessment

Capability Axes

An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read

AI Capability
AA on AI CentralityThe artificial intelligence is the product. Remove the model and there is nothing left to sell.
Vendor Published

Every output of the md suite is model output. mdbrain segments brain structures to give regional volumes, finds and characterizes MS and dementia lesions, flags saccular aneurysms and differentiates brain tumors; mdprostate segments the gland and its lesions; mdknee grades cartilage defects. The PACS connections, automatic pulling of prior exams and structured reports exist to deliver those findings.

The practice already owns the scanner, the viewer and the radiologist. Remove the learned image analysis and the suite has no measurement, overlay or report to send, so what an imaging center pays for per examination is the analysis itself.

BB on Autonomy and Oversight ModelThe oversight structure is described and one part is missing, commonly the threshold at which the system stops or what happens after it is wrong.
Vendor Published

The radiologist reads every result. mdbrain and mdknee send overlays and reports into PACS beside the original images, where they become part of the radiologist's read, and the mdprostate workstation lets the reader adjust segmentations and findings and decide when the report leaves the workstation. A site can also choose automatic routing of results into PACS. The US mdprostate label limits the software to segmentation and measurement for interpretation by trained clinicians.

No threshold flags an analysis as unreliable, for example after motion or a protocol outside the recommended sequences, and no step follows up a missed finding. The mdbrain page claims 100% sensitivity for saccular aneurysms larger than 5 millimeters with no source attached, a claim the radiologist's own read of the angiogram is there to answer.

BB on Model and Technology TransparencyThe approach or the suppliers are named without the version and update discipline behind them. Naming a supplier is the entry to this band both here and on Model Supply Chain Disclosure, which ask different questions of the same disclosure: who receives the data, and what produces the output.
Regulatory Filing

The models are deep learning segmenters, described module by module. mdprostate's cleared algorithm segments the prostate on T2 weighted images with diffusion weighted images and the apparent diffusion coefficient map as added inputs, and mediaire notes that its training data contains no 3D T2 cases, so it recommends 2D T2 sequences. For mdbrain, a 2022 Frontiers in Neuroscience paper describes a triplanar U Net with lesion wise voting for new MS lesions, and an AJNR external validation covers aneurysm detection.

The brain module versions are numbered in publications, mdbrain 4.5 among them, but no customer facing release history or change notes are published, and under the subscription customers receive updates automatically without a stated schedule.

BB on Model Supply Chain DisclosureSubstantial partial disclosure, or a chain that is structurally short: an in house build, a cleared model that cannot be quietly swapped, or a deployment where the transfer does not occur at all. Naming the model provider exits the band below into this one; the axis rises from here on the completeness of the party list and on the terms that govern data once it arrives.
Vendor Published

In the standard installation the chain ends at the hospital wall. The md suite runs on a local Linux server at the practice or hospital, studies arrive from its own scanners and PACS, and the models produce segmentations and reports there, with no transfer to mediaire or a cloud model provider. The FAQ states that patient data and reports never leave the premises, even in anonymized form.

Two hosted paths sit outside that: mdprostate can run in the cloud under its US description, and mdbrain reaches European hospitals through Incepto's platform, which Incepto hosts on certified EU infrastructure under its own terms. For those paths the cloud host, processors and data terms are not published by mediaire.

BB on Clinical and Operational EvidenceNamed deployments with dated outcome figures and enough method to test them, or published research short of independent validation.
Vendor Published

mdbrain has the deeper evidence base, 43 published clinical studies by mediaire's count. A real life evaluation at five sites had seven radiologists read 285 brain MRIs for dementia and MS, 128 with mdbrain support and 157 without, and median reading time fell 25% with the software, 57% for dementia and 13% for MS. AJNR published an external validation of aneurysm detection on time of flight angiography in 2022, and an ESR 2022 abstract compared mdbrain 4.5 MS lesion segmentation with a pool of experts.

For mdprostate, a retrospective study compared the software with routine reads against biopsy in 1,000 patients. Spedali Civili Brescia and several German practices give testimonials, and no named site reports a measured outcome from its own deployment.

BB on AI Safety and PHI StewardshipCategorical commitments are published, such as no training on customer data, without the retention schedule behind them.
Vendor Published

The local design is a categorical commitment. The md suite is installed in the practice or hospital, and mediaire's FAQ says patient data and reports never leave the premises, not even in anonymized form, so analysis needs no anonymization and no study is sent to mediaire for processing or model training. Results go into the site's own PACS.

The commitment covers the local installation only. The cloud option for mdprostate and the Incepto hosted mdbrain run on other infrastructure, and for them mediaire states no retention period, no training restriction and no handling of the images it receives.

Regulatory and Compliance
CC on HIPAA and BAA PostureA status is stated but not supported: compliance is claimed, or business associate status stated, without the underlying document, including where the only privacy notice published covers the website rather than the service that handles patients. The mirror case grades here as well: a substantive privacy document that reaches the service, with no statement of business associate status anywhere and no scope position taken. One of the two elements the band above asks for is present, which is a grade below it and not a grade at the floor.
Vendor Published

The standard installation keeps protected health information away from mediaire. Images, analysis and reports stay on the provider's own server and PACS, so a practice using the local md suite does not send identifiable studies to the company.

mediaire says nothing about HIPAA or business associate status, and its privacy policies cover the website and the demo service rather than clinical use. The cloud deployment of mdprostate, the route most likely to reach US practices, has no published business associate agreement or privacy terms, and Incepto's European service runs under Incepto's own GDPR terms. The no transfer design is stated in product terms, without a service privacy document that takes a position on patient data.

BB on Security Certifications and Trust CenterA recognized certification is named in the vendor own material without the artifact, or with a scope or renewal question the buyer has to raise. A recognized certification here is an audit of how the vendor operates security, such as SOC 2, HITRUST or ISO/IEC 27001. A certification has a scope and a clock, and both are part of this grade. A certification the vendor attaches to its data center, hosting facility or cloud provider, rather than presenting as its own, is the host's and does not count here.
Vendor Published

ISO 27001 is the named certification. mediaire's solutions are CE marked and, in the company's own words, developed under ISO 13485 and ISO 27001 certifications, and the mdprostate 510(k) included FDA's review of software and cybersecurity controls. In the standard installation most of the attack surface is the customer's own server, which receives studies over the hospital network.

No certificate, issuing body, scope or renewal date is posted, the md suite page carries a data security heading with nothing beneath it, and no trust portal or penetration test summary is offered. Whether the certification covers the mdprostate cloud environment is not stated.

AA on FDA and Regulatory StatusThe regulatory position is unambiguous and verifiable: a clearance or authorization identifiable in the public databases, with the version and indication it actually covers. A product outside device regulation reaches this band when the vendor publishes why, naming the exclusion it relies on, and markets nothing past it.
Regulatory Filing

FDA cleared mdprostate under K252571 on August 7, 2026, for automatic segmentation, visualization and volumetric quantification of the prostate on three dimensional MRI in men aged 35 to 99 with suspected tissue changes, with trained clinicians interpreting the images. That is the only US clearance in the suite.

In Europe, mdprostate carries Class IIb CE marking, with its certificate posted, and is sold with a PI RADS 2.1 lesion assessment workflow that the US clearance does not cover. mdbrain and mdknee are CE marked medical devices with no class stated and no FDA clearance, so US buyers can rely on a cleared indication only for prostate segmentation and volume.

BB on AI Governance and Bias DisclosureA governance framework with named process behind it, such as certification to an artificial intelligence management standard, or material written for a customer own review committee to evaluate the product with. A framework covering the vendor whole portfolio counts when its scope reaches this product; what it cannot supply is the product specific evaluation the band above asks for. Published results within the one group where the performance of this product is most at risk also sit here: evaluation on the question this axis asks, short of the comparison across groups the band above requires. A medical device clearance or certification, and the quality system behind it, does not reach this band on its own; it is graded under regulatory status. A regulator reviewed plan governing how the model may change does reach it.
Regulatory Filing

Stratified results exist for one function. The mdprostate 510(k) summary reports segmentation performance by age group, prostate volume, lesion status and scanner field strength, with mean Dice overlap of 0.89 to 0.91 across those strata and boundary distance as a second measure of error.

That comparison covers prostate segmentation and volume, a secondary module. mdbrain, the lead product with its volumetry, MS lesion, aneurysm and tumor analyses, has no results published by age, disease stage, scanner vendor or field strength, though it is sold for 1.5 and 3 tesla systems from four manufacturers, and the European PI RADS lesion workflow has none either. The evaluation answers the question for one part of the suite rather than across what the suite does.

CC on AI Liability and RecourseMechanisms exist that let someone challenge an output, such as audit trails, source traceability or review before commit, with nothing standing behind the output and no route for the harmed party.
Vendor Published

The workflow lets a radiologist challenge a finding before it reaches the report. Overlays sit on the original images in PACS, longitudinal views compare the current exam with prior ones so an implausible change in volume stands out, and in the mdprostate workstation the reader edits segmentations and findings and controls release.

mediaire takes on no obligation once a report goes out. No accuracy guarantee, correction process or remedy attaches to a wrong volume, missed lesion or false aneurysm flag, and the 100% aneurysm sensitivity on the mdbrain page carries no source a site could hold the company to.

Integration and Deployment
BB on EHR and Interoperability DepthNamed systems with read access or one directional writing, or standards support with named deployments behind it.
Vendor Published

Integration is imaging native and named. The md suite reads DICOM from Siemens, Philips, GE and Canon or Toshiba scanners, pulls studies and priors from PACS automatically, and sends results back with Auto Send, with tumor results shown as overlays in the local PACS; mediaire says it works with all common PACS. mdprostate exports RTStruct contours for fusion biopsy systems.

Sectra distributes mdbrain through its AmplifierStore, Incepto added mdbrain to its platform in October 2026, and Mint Medical connects its mint Lesion reporting to mdprostate. Those are read and write paths into imaging systems. No RIS or electronic health record connection is named, and results reach the chart only through the radiology report.

BB on Deployment Model and Data ResidencyOptions and residency are stated with isolation or the processing path left open.
Vendor Published

The default is on premises. mediaire installs the md suite remotely, often within a day, on a local Linux server with at least a four core Intel i7, 16 GB of memory and 500 GB of storage, a graphics card shortening analysis, and images, analysis and reports stay at the practice or hospital.

Two hosted routes exist beside it. mdprostate can run in the cloud according to its US description, and Incepto offers mdbrain on its own infrastructure within the European Union. For mediaire's cloud option, the region, tenant isolation and where processing happens are not stated, so residency is clear for the local suite and open for the hosted one.

Commercial
CC on Commercial TransparencyNo price is published and the posture is discoverable: a buyer can establish how the product is sold and what drives the cost before contacting the vendor. Most of the index sits here.
Vendor Published

The structure of the charge is published. The md suite is billed as a service, and a site pays a usage fee that depends on its monthly volume of examinations, a one time installation fee and a monthly service fee, with no software purchase. mdprostate is sold in tiers by examination volume, and a free web based demo is open to anyone who registers.

No figure is attached to any fee, tier boundary or per examination rate, and an on premises trial is arranged by email. A practice can see what drives its cost, volume, installation and service, but not what it will pay before talking to mediaire.

BB on Setting and Specialty CoverageCoverage is named with validation behind part of it.
Vendor Published

The modules name their settings precisely. mdbrain covers dementia, multiple sclerosis, atypical parkinsonian syndromes, saccular aneurysms and brain tumors on recommended sequences such as 3D T1 MPRAGE, 3D FLAIR and time of flight angiography; mdprostate covers prostate MRI for men with suspected disease; mdknee covers cartilage on fat suppressed proton density images; all run on 1.5 and 3 tesla systems in outpatient practices and hospital departments.

Validation is uneven. Dementia and MS reading has a multisite evaluation, aneurysm detection an external validation, and prostate a biopsy referenced study and the FDA analysis. Tumor differentiation, parkinsonian volumetry and knee cartilage grading have no published validation on the product pages.

Alternatives

Alternatives to mediaire

Other products that do the same kind of work as mediaire, and what each one does.

Gleamer SAS is a radiology AI company based in Saint-Mandé, on the edge of Paris, and since 2 March 2026 part of DeepHealth, the digital health subsidiary of the US imaging services operator RadNet, Inc.

Belgian company, founded in 2011 in Leuven and now part of GE HealthCare, whose icobrain software measures the brain on MRI and CT.

Quibim, a Valencia company named for quantitative imaging biomarkers in medicine, turns medical images into measurements and predictions and sells AI software as a medical device to hospitals alongside a platform and services for biopharma, after a commercial launch in 2021.

Bot Image, based in Omaha, Nebraska, sells ProstatID, FDA cleared hosted software that helps physicians qualified to read prostate MRI identify regions suspicious for cancer and assess their likelihood of malignancy in screening and diagnostic exams.

ANDI, short for Advanced Neuro Diagnostic Imaging, is brain MRI analysis software from Imeka Solutions in Sherbrooke, Quebec.

Better Medicine builds AI for reading abdominal CT, starting with BMVision Kidney, which detects kidney lesions as small as 5 mm, draws their boundaries in 3D, measures the longest dimension and three orthogonal axes, and separates likely malignant from benign findings for a radiologist to review.

Commercial

Pricing

Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.

Entry Price Pricing Basis BAA Tier Implementation Source
Per examination volume, by quote
Billed as a service: a usage fee set by monthly examination volume, plus a one time installation fee and a monthly service fee. mdprostate is sold in volume tiers. No figures are published. The local installation keeps imaging data on site. No business associate agreement or HIPAA position is published for the cloud option. A one time installation fee applies, with no amount published. mediaire installs the suite remotely, often within a day. Vendor Published

A free web based demo is open after registration, and on premises trials are arranged by email. Tier thresholds and rates are set in the sales discussion.

Contact us

Found a vendor we missed? Have feedback on the index? We’d love to hear from you.