ANDI
ANDI, short for Advanced Neuro Diagnostic Imaging, is brain MRI analysis software from Imeka Solutions in Sherbrooke, Quebec. It processes diffusion and T1 weighted scans, reconstructs white matter fiber bundles and measures how water diffuses along them. It uses constrained spherical deconvolution to resolve crossing fibers and uses AI during brain extraction. An optional segmentation model adds volumes for larger gray matter structures. The report maps 33 fiber tracts and flags measurements outside age and sex matched reference ranges drawn from more than 1,440 control subjects. It supports comparison with earlier exams. Imeka offers cloud processing and installation at an imaging site. The results open in a system that reads DICOM images.
FDA cleared ANDI 2.2 in May 2026 under K261405. The release extended the normative reference to include people aged 16 and 17 while keeping the analysis and output structure from ANDI 2.0. Radiologists and neurologists interpret the report in the context of the exam. The report provides quantitative measurements and leaves diagnosis to the physician.
Imaging clinics in about 150 cities across 30 states offer ANDI exams, and RAYUS Radiology offers it at its DeSoto and McKinney locations in Texas. A peer reviewed 2024 study by Rahmani and colleagues used the original ANDI workflow for 21 participants with compatible brain scans from a traumatic brain injury cohort. Imeka offers demonstrations of the reporting and acquisition workflow.
Capability Axes
An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read
The imaging pipeline turns diffusion and T1 weighted MRI scans into measurements and images of white matter tracts. Imeka uses constrained spherical deconvolution to resolve crossing fibers, then reconstructs and measures bundles against a normative reference. In ANDI 2.2 the diffusion workflow is characterized as a deterministic processing pipeline with AI in skull stripping. A separate optional learned segmentation step adds gray matter volumes to the output.
Earlier clinical research described reinforcement learning during whole brain tractogram reconstruction in the original ANDI workflow. The current product centers on quantitative diffusion mapping, supported by learned preprocessing and the added regional volumes. Without the learned preparation and optional volumes, the deterministic diffusion analysis still describes white matter tracts and compares them with the reference when processing prepared scans.
The imaging software runs reconstruction and measurement automatically, then returns maps, graphs and reference comparisons to the physician. The physician sees how a patient's tract measurements compare with an age and sex matched group and can assess change across scans. The indication treats those outputs as adjunctive information and requires the clinician to review the case, with clinical judgment and further action outside the model's role.
Bench testing of gray matter segmentation used regions corrected by an expert and approved by neuroradiologists. The clinical arrangement places the physician in charge of interpreting the report. It has no defined escalation or correction process when the report misidentifies a structure or the input quality is insufficient.
The software reconstructs white matter using constrained spherical deconvolution to resolve crossing fibers and compares measurements with a reference matched by age and sex. Each bundle is extracted per subject rather than from a standard atlas. ANDI 2.2 uses AI for brain extraction and offers a separate segmentation model for gray matter volumes.
The filings distinguish the optional segmentation from the white matter processing and identify a pretrained brain segmentation algorithm trained on images from 140 subjects and evaluated in an independent 747 subject dataset before product integration. The 2.2 release preserves the algorithms while extending the reference group. The segmentation tool's supplier and model release, the current make up of the full reference and how often models change are not named.
The white matter analysis runs inside ANDI, which may be installed locally or run through Imeka's cloud. The product has an optional pretrained brain segmentation algorithm from another supplier. Regulatory testing evaluated it after processing scans within the ANDI pipeline, using differently sourced images for its product performance assessment. The input is diffusion and T1 weighted imaging.
Its DICOM compatible report lets the facility view the affected bundles and their measurements within its own imaging workflow. Neither the segmentation supplier nor the cloud processor is named, and no processor terms restrict access to identifiable scans, their retention or their reuse for training in the hosted service.
RAYUS Radiology offers ANDI in DeSoto and McKinney, Texas. In the peer reviewed 2024 Rahmani study, 21 people from an original cohort of 65 referred to Neurevolution Medicine had diffusion acquisitions that were analyzed with ANDI. That work used the original software and other applications for most of its quantitative comparisons. The ANDI 2.0 filing tested gray matter segmentation against expert approved regions in 71 cases and tested repeatability in 59 healthy people.
The 2.2 release retained the processing algorithms and expanded the normative dataset to ages 16 and 17. There was no new clinical trial for 2.2, and the RAYUS deployment carries no measured outcome for that release.
The product processes diffusion and T1 brain images and presents derived measurements alongside reference data. The facility may install it locally or have its images processed in Imeka's hosted environment. Physician interpretation remains part of the workflow, including review of the complete clinical information before a diagnosis.
The optional segmentation adds regional volumes, and the training and evaluation datasets in its regulatory filing are described separately from the clinical workflow. The report and scans may contain sensitive information. The clinical service has no terms establishing which identifiable images are retained in the cloud, when they are deleted, whether they are used for later training or how an error involving patient data is investigated.
The clinical workflow accepts brain MRI images for processing either at the site or through the hosted service. It creates measurements, visualizations and a report for a physician with compatible DICOM software. For each exam it shows maps and reference comparisons for 33 fiber tracts. A report can also compare the current scan with an earlier exam. Imeka has a service channel for imaging customers, and its support privacy policy covers the support website and its users.
The general company notice covers information collected through website forms and contact data. The software offer has no business associate commitment or equivalent processor agreement that governs the transfer or handling of the scans and reports themselves.
ANDI runs in a secure cloud environment or on infrastructure at a radiology facility. The regulatory submission for the 2.0 software identifies testing against medical device risk and software life cycle standards and addresses FDA cybersecurity guidance. The 2.2 modification preserved the processing pipeline and went through risk analysis and performance testing for its reference data expansion. Those reviews cover the device design and its deployment. No SOC 2 report, ISO 27001 certificate or other audit of Imeka's cloud operations sits beside them, and the support website is a separate system with its own account privacy terms.
FDA cleared ANDI 2.2 on May 28, 2026 under K261405 as automated radiological image processing software. The indication covers display and processing of MR images, atlas assisted visualization, segmentation and volumetric quantification of segmentable brain structures. Reports are generated for systems that read DICOM image sets. The release retains the clinical processing functions of ANDI 2.0 and extends the normative reference to subjects aged 16 and 17.
The marketing emphasizes finding subtle white matter changes and assessing brain injury. The device indication is narrower and describes quantitative adjunctive information for a trained physician, without prediction, diagnosis or interpretation of brain health. The physician reviews the report as part of a broader clinical assessment.
ANDI 2.2 extends the normative reference used for white matter measurements to people aged 16 and 17. The regulatory evaluation compared outputs for the expanded age group with adults and found no clinically meaningful differences under acceptance criteria based on white matter characteristics. ANDI 2.0 also tested its optional segmentation across scanner models and disease groups and supplied stratified results for review, with numerical ranges by region type.
Imeka matches the white matter reference by age and sex, against more than 1,440 control subjects. The adolescent comparison covers the core diffusion output of the release on sale, but neither filing publishes the size of each age, sex and disease group in the 2.2 reference or the error results compared group by group.
The clinician receives a quantitative report with images, measurements and a reference comparison and makes the final clinical interpretation. The physician is responsible for considering all of the patient's other findings before diagnosing or selecting care. The scan and report give the reader a way to inspect the anatomy and results against the underlying images, including comparisons with past exams. Imeka provides a support site for users and contact for the clinical product.
Its website terms limit responsibility for that website. No clinical contract term requires Imeka to correct a mistaken segmentation, reprocess a failed exam or compensate for harm from a clinical output.
The software accepts diffusion and structural brain MRI from an imaging center and outputs results for a system that reads DICOM. It works across scanner manufacturers with a single shell diffusion sequence of five to eight minutes on 1.5T or 3T equipment. Imeka helps a site set up that acquisition sequence. It runs without a separate graphical interface, so images and reports are viewed in the site's existing imaging workflow. RAYUS Radiology offers scans using ANDI at two named sites.
An earlier GE HealthCare BrainWave agreement concerns Imeka's diffusion technology. The current connection is defined by DICOM support, with no specific archive or record system named for receiving its reports or writing fields back at RAYUS.
The processing service can run at the imaging facility or as hosted software. The deployed processing service takes brain MRI scans and returns a report for systems compatible with DICOM without a dedicated graphical interface. In a local installation, the processing workload runs at the customer's own facility. Imeka's clinical product also offers automated reports through a secure cloud environment.
The company operates from Sherbrooke and has a US office, while the chosen installation determines how the imaging site routes exams. The hosted service carries no storage location commitment for brain images or reports. For a facility installation, there is no defined route for any study data that might travel beyond the site.
Imeka offers ANDI to imaging practices through a demonstration of the scan acquisition, processing and report. The system can run as cloud software or be installed in the facility. The service guides a site on the short diffusion sequence that supplies the input and presents the results in a system capable of reading DICOM images. Radiologists and neurologists use the resulting report during evaluation. Imaging providers also offer appointments for scans processed with ANDI.
The imaging appointment buys the exam rather than the software license. Imeka sells the application through a sales conversation without plan figures, a defined charge unit or a self service trial for the clinical software.
Neurologists and radiologists who review brain MRI use the product, mostly through outpatient imaging. It processes images from a 1.5T or 3T scanner using a diffusion acquisition and T1 sequence. ANDI exams are offered at imaging clinics in about 150 cities across 30 states, from Arizona, California, Florida and Texas to Ohio and Washington, and RAYUS Radiology offers it in DeSoto and McKinney, Texas. Imeka sells it for traumatic brain injury and other white matter conditions.
The original ANDI software was studied in a subgroup of patients with a history of traumatic brain injury. Current generation bench testing included images from people with multiple sclerosis, Parkinson's and Alzheimer's, and the 2.2 reference now includes adolescents aged 16 and 17. No study measures diagnostic performance across every condition the marketing names.
Alternatives to ANDI
Other products that do the same kind of work as ANDI, and what each one does.
Belgian company, founded in 2011 in Leuven and now part of GE HealthCare, whose icobrain software measures the brain on MRI and CT.
Bot Image, based in Omaha, Nebraska, sells ProstatID, FDA cleared hosted software that helps physicians qualified to read prostate MRI identify regions suspicious for cancer and assess their likelihood of malignancy in screening and diagnostic exams.
Foqus Technologies, a Kitchener, Ontario company cofounded by Dr. Sadegh Raeisi, sells DeepFoqus-Accelerate, AI reconstruction software that lets an MRI department scan the brain up to four times faster.
mediaire, a Berlin company founded in 2018, sells the md suite, MRI analysis software that radiology practices and hospital departments install on their own network.
Quibim, a Valencia company named for quantitative imaging biomarkers in medicine, turns medical images into measurements and predictions and sells AI software as a medical device to hospitals alongside a platform and services for biopharma, after a commercial launch in 2021.
Seoul based MRI AI company with US operations. SwiftMR is a deep learning enhancement tool that reduces noise and sharpens MRI images after acquisition, so sites can scan faster or get better images from the same scan.
Pricing
Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.
| Entry Price | Pricing Basis | BAA Tier | Implementation | Source |
|---|---|---|---|---|
|
Contact Imeka
|
Imeka sells the clinical imaging software through a demonstration. An imaging site can use hosted processing or install ANDI locally. The sales discussion covers the acquisition sequence, figures for the site and the clinical reporting workflow. | ANDI accepts brain MRI for processing. A clinical business associate or processor agreement is part of contracting rather than the website and support privacy terms. | Imeka helps sites configure the diffusion acquisition used by ANDI. Setup and local installation fees depend on the facility's commercial agreement. | Vendor Published |
The imaging site uses a DICOM capable system to review ANDI outputs. Patient appointments for scans processed with ANDI are separate from the facility subscription. A rate for a site, exam or subscription level is not listed.