ForeseeHome
ForeseeHome is Notal Vision's prescribed home monitoring program for people with intermediate dry age related macular degeneration at risk of converting to wet AMD, sold under its own brand beside Notal's SCANLY home OCT service. Patients with stable fixation take a short test one eye at a time on a small device that maps perceived distortion in the central 14 degrees of vision using Preferential Hyperacuity Perimetry. Each test goes to the Notal Vision Monitoring Center, where a machine learning comparison, in use since the device's 2009 FDA clearance, checks it against a normative database of intermediate AMD tests and against the baseline set when the patient started.
When the comparison finds a change that needs attention, an alert is generated, reviewed at the Monitoring Center and sent to the referring retina specialist, ophthalmologist or optometrist, who sees test history through the Eye Care Professional Portal around the clock and decides whether to examine the patient. Monitoring supplements regular visits rather than replacing them.
The peer reviewed HOME randomized trial followed 1,520 participants at 44 centers for a mean of 1.4 years. At detection of neovascularization the median loss was four letters with ForeseeHome plus standard care against nine with standard care alone. Notal lends the device and bills monthly monitoring under CPT 0379T, at $77.90 a month self pay or $15.58 under traditional Medicare Part B after the deductible.
Capability Axes
An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read
The alert is the program's working output, and a learned comparison produces it. Notal has used machine learning since the 2009 clearance, checking each home test against a normative database of intermediate AMD results and against the patient's own baseline, and the change it flags is what sends a patient back to the clinic between scheduled visits.
Remove that comparison and the device would still present stimuli and record responses, and the portal would still chart them, but nothing would tell a practice which of its monitored patients to see now. The hardware, the Monitoring Center's review staff and the benefits and billing service carry value of their own, so the model is the engine of the core monitoring capability rather than the whole product.
Two reviews stand between the algorithm and any clinical action. An alert is generated when a test shows a change from baseline that needs attention, the Monitoring Center reviews it, and the referring eye doctor, who has round the clock portal access to the testing data, decides whether the patient needs an examination and whether the change reflects conversion or a reason to keep testing.
Patients keep their regular visits, and the FAQ says the device "should be used in addition to the doctor's recommended care program." The trigger criteria sit inside the cleared algorithm, beyond a practice's reach in the portal, and no workflow covers withdrawing an alert that review shows was wrong or telling the patient and the practice that it has been withdrawn.
Preferential Hyperacuity Perimetry is the named measurement method. It quantifies how a patient perceives distortion within the central 14 degrees of vision, and the analysis maps areas of distortion that may change as disease progresses.
The learned part compares results with "a normative database that includes testing data of patients with intermediate age-related macular degeneration" and with the patient's baseline, and Notal's March 2026 newsletter says machine learning has been part of the device since its 2009 clearance. The function and the development population are therefore clear. The size of that database, the model type, and any version or validation history since 2009 carry no detail, so whether today's algorithm is the one the HOME trial tested goes unanswered.
The chain is short and Notal owns it. The home device, the change detection engine, the Monitoring Center whose staff review alerts, and the portals for practices and patients are all Notal Vision's, so no outside model provider handles a test result between the patient's eye and the referring doctor, and the cleared analysis cannot be swapped without regulatory consequence.
Beneath that service the parties carry no names: the network that transmits results from the home, the hosting provider that stores test histories, and the retention terms those parties hold data under. Notal's clinical privacy notice governs the information in its possession and reaches the monitoring service, but it lists no service providers by name.
Two peer reviewed studies stand behind the device. The HOME randomized trial followed 1,520 participants at 44 centers for a mean of 1.4 years, and at confirmed neovascularization the median loss was four visual acuity letters with ForeseeHome plus standard care against nine with standard care alone.
The 2022 ALOFT retrospective cohort covered 3,334 eyes from five named retina practices between 2010 and 2020, 995 of them at Elman Retina Group, and 84% of the 285 converting eyes kept 20/40 acuity or better at conversion. A later ALOFT sub analysis found patients whose alerts did not end in a wet AMD diagnosis were "nearly twice as likely to convert to wet AMD" afterward. Both studies used the ForeseeHome perimeter, neither names a software build, and ALOFT pools its outcomes rather than reporting them practice by practice.
Test data moves from the home device to the Monitoring Center, which holds and reviews it as a health care provider under Notal's clinical privacy notice, and the referring practice sees what it needs through its portal. The notice explains treatment, payment and operations uses, permits certain research uses where legal safeguards are met, and requires written authorization for other uses. The questions an AI program raises reach further.
No retention schedule applies to home test histories, no de identification method is described for research use, and nothing excludes new patient tests from refining the normative database the alerts depend on. Clinical review of every alert is the safety layer in place, with no process for reporting or investigating an algorithm failure such as a missed conversion.
Notal Vision acts as a health care provider here, not as a business associate. The Monitoring Center supports diagnosis and monitoring, bills the technical monitoring component to the patient's insurer and shares relevant information with the referring practice, and its notice of privacy practices governs the health information it holds, with routes to access records, request amendments and restrict disclosures. Covered entity status is stated, with a substantive notice behind it.
No business associate agreement is offered for the referral relationship, since the practice and Notal each treat the patient under their own obligations. The web privacy policy covers information collected through the site separately from the clinical notice.
Patient results travel from the home device to Notal Vision for review, and the referring office and the patient each use separate portal access. The Monitoring Center works under clinical privacy duties, including safeguards for the health information it holds and procedures for handling disclosures. No independent check stands behind those safeguards.
No SOC 2 report, ISO 27001 certificate or penetration test summary covers the device, the transmission path or the portals, and the 2009 clearance predates FDA's premarket cybersecurity expectations, so unlike the SCANLY home OCT authorization it carries no reviewed cybersecurity file. For a device that sits in patients' homes and reports to a central service, security rests on Notal's own description of its controls.
FDA cleared the Foresee Home home perimeter on December 23, 2009 under K091579. The indication is "detection and characterization of central and paracentral metamorphopsia (visual distortion)" in patients with age related macular degeneration, as an aid in monitoring progression including changes related to choroidal neovascularization, and the FAQ adds that "It is intended to be used at home for patients with stable fixation."
The device is "available by prescription only" and used in addition to the doctor's care program. The program sold today adds Monitoring Center review on top of the cleared device, and the treating practitioner keeps diagnostic and treatment decisions. Medicare covers the test for patients with intermediate dry AMD at risk of wet AMD.
The reference population is defined, and one at risk group has published results. The comparison uses a normative database of intermediate AMD tests and requires stable fixation and a usable baseline, which sets who the device is for. In the ALOFT cohort, alerts contributed to detecting 56% of conversions when the fellow eye had intermediate AMD and 47% when it had neovascular AMD, with no statistically significant difference between the two.
Those are shares of detected conversions rather than sensitivity. No result compares false alert rates or detection across age, sex, race, baseline acuity or the steadiness of a patient's fixation, the factors most likely to change how well a perimetry test reads for a given patient.
Two clinical reviews sit between an alert and a decision, and a patient keeps the rights the privacy notice grants. The Monitoring Center reviews alert data before it reaches the referring practice, and the treating specialist can examine the patient and investigate any mismatch between the home test and the clinic findings. Notal accepts requests to amend health information it created, with a written review step, a route that corrects the record rather than the algorithm's output.
No warranty, remedy or correction commitment attaches to a missed conversion or a false alert. The device is positioned as an aid used alongside regular care, which places the consequence of a missed change on the patient's ongoing examinations.
Integration stops at Notal's own portals. The referring office uses the Eye Care Professional Portal to see each patient's testing and receives notification after an alert is reviewed, and patients have a portal view of their own results. Ordering runs through Notal's enrollment process rather than an order placed in the EHR.
No connection to an EHR or an ophthalmology practice system is named, and no interface writes alerts or test trends into the chart, so a practice that wants an alert in its record copies it there by hand. Notal's SCANLY service keeps the same separation between its portal and the practice record, and neither program offers an API for pulling results into another system.
The program runs as a single hosted service. Testing happens on the home device, results transmit automatically to the Notal Vision Monitoring Center, where the comparison runs and staff review alerts, and practices reach the data through a web portal without installing anything locally. Notal operates the service in the United States from Manassas, Virginia, and bills Medicare and domestic insurers for it, so a US location follows from how it is sold.
The clinical notice and the web policy commit to no storage location, host or region for the test histories the Monitoring Center keeps. No alternative deployment exists for a health system that wants test data held in its own environment.
Patients pay a stated monthly fee and receive the device on loan. Notal Vision lists $77.90 a month without coverage, and $15.58 a month under traditional Medicare Part B without a supplement once the deductible is met, which may fall to $0 with a qualifying supplemental plan. The Monitoring Center verifies benefits, handles authorization and claims for the monitoring component under CPT 0379T, and provides monitoring at no cost while it pursues eligible insurance appeals.
Medicare Advantage and commercial plan costs depend on verification. Enrollment starts with an eye care professional's prescription rather than a sales conversation, and ForeseeHome is billed separately from Notal's SCANLY home OCT service.
Coverage is narrow and studied. The prescribed use is home testing for people with age related macular degeneration and stable fixation, centered on intermediate dry AMD at risk of progressing to wet AMD, and Medicare covers that assessment subject to its requirements. Retina specialists, ophthalmologists and optometrists prescribe and review, while the Monitoring Center handles enrollment and getting patients started.
The HOME randomized trial studied high risk eyes across 44 clinical centers, and ALOFT followed referred patients at five retina practices in routine care over ten years, so both the specialist setting and the patient group have trial and real world results behind them. Patients without stable fixation, or with established wet AMD, sit outside the indication.
Alternatives to ForeseeHome
Other products that do the same kind of work as ForeseeHome, and what each one does.
Notal Vision's SCANLY Home OCT is a prescribed home imaging program for people already diagnosed with neovascular, or wet, age related macular degeneration.
Respiratory diagnostics company developing Sylvee, a chest worn wearable that projects low frequency sound into the lungs and analyzes the returning resonance with machine learning to measure lung volumes, trapped air, respiratory rate and breathing sounds, positioned for early COPD…
AMC Health runs remote patient monitoring and virtual care programs for health plans, health systems, rural providers, employers, government programs including the Veterans Health Administration's Home Telehealth contract, and decentralized clinical trials.
Biofourmis monitors patients at home and tries to detect deterioration before it becomes an admission.
Empatica makes medical grade wearables and the algorithms and software behind them, for clinical research, epilepsy and Parkinson's disease.
AI enabled chronic care management for older adults, run in partnership with health systems: AI agents monitor daily vitals from connected devices in patients' homes and handle medication titration, lifestyle coaching, alert triage, care coordination and symptom assessment, working with…
Pricing
Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.
| Entry Price | Pricing Basis | BAA Tier | Implementation | Source |
|---|---|---|---|---|
|
$77.90 per month self pay
$77.9 baseline
|
The monthly monitoring fee is $77.90 without insurance. The device is loaned at no additional charge. Traditional Medicare Part B without a supplement is $15.58 a month once the deductible is met. With a qualifying supplemental plan, out of pocket cost may be $0. | The monitoring center provides healthcare directly and handles protected health information under its clinical privacy notice. | The device is loaned without a separate fee. The Notal Vision Monitoring Center verifies benefits and handles authorization, enrollment and claims for monitoring. | Vendor Published |
The program begins with a referral from the patient's eye care professional. Notal bills the monitoring component under CPT code 0379T. Monthly costs for other insurance plans depend on verification. Notal provides monitoring at no cost while it pursues eligible insurance appeals.