Clinical Trials AI
C

Carina AI

Carina AI is the trade name of Carina Medical LLC, founded by researchers from the University of Virginia and the University of Kentucky. Its CuratAI platform builds research cohorts from PACS, EHR and pathology data. A local language model turns clinical notes and reports into structured registry fields. The platform removes identifiers from headers, dates, images and text, and keeps the file used to link the research data back to patients inside the institution. Annotators draw on selected image slices, let the model interpolate the remaining contours and send the work for approval. Researchers can also run their own models against the resulting cohort on hospital hardware.

University of Pennsylvania investigators compared Carina’s image deidentification with three other tools in 185 brain and head and neck patients. Carina preserved the volumes of the structures studied. In radiation oncology, INTContour drafts structures for treatment planning, and INTDose independently recalculates dose for quality assurance. The FDA cleared both in 2022 for specific functions. At Mayo Clinic Arizona, researchers retrained INTContour on 100 prostate cases with their local protocol and used blinded physician review on 115 test cases. CuratAI shares only deidentified project data after an authorized user initiates the transfer.

AI Health Index verifiedNovember 24, 2026
Compare Carina AI with other vendors
Founded
—
Headquarters
—
Website
carinaai.com/
Categories
clinical-trials-ai, radiology-and-imaging-ai
Indexed Products
CuratAI, INTContour, INTDose, OncoAI Suite, QuantBrain, NeuroStage
Buyer Segments
Academic Medical Centers, Clinical Research Teams, Radiation Oncology Departments, Medical Physicists
Assessment

Capability Axes

An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read

AI Capability
BB on AI CentralityThe model is the engine of a core module. The platform carries other value, but this capability does not exist without it.
Vendor Published

CuratAI uses a local language model to extract structured registry fields from clinical notes, reports and PDFs. It also uses optical character recognition and language model reasoning to distinguish identifying text from useful labels in an image. During annotation, a model fills the slices between an annotator’s sample contours for a person to check.

The service also performs work that does not require the models, including retrieval, DICOM header rules, date shifting and signed project sharing. In the clinical portfolio, INTContour uses trained segmentation models and INTDose performs an independent Monte Carlo recalculation for quality assurance.

AA on Autonomy and Oversight ModelWhat the system may do and what it may not do are both published, with escalation thresholds, override paths and the conditions that route a case to a person.
Vendor Published

The registry workflow assigns each extracted field a confidence level. In the STAR registry validation, 86% of fields landed at level 1 with about 89% accuracy and were accepted automatically, and the 14% at levels 2 and 3 went to staff for review. For image annotation, the person approves or corrects interpolated contours in a shared queue. The system records the user, timestamp and each reversible edit.

CuratAI also blocks sharing until the artifacts have gone through the deidentification pipeline and requires someone to initiate an export. Signed tokens restrict a collaborator to the approved project. In INTContour, a qualified clinician reviews and can edit contours before they are used.

BB on Model and Technology TransparencyThe approach or the suppliers are named without the version and update discipline behind them. Naming a supplier is the entry to this band both here and on Model Supply Chain Disclosure, which ask different questions of the same disclosure: who receives the data, and what produces the output.
Vendor Published

CuratAI extracts data with a local model described as having seven billion parameters, with a 12 GB graphics processor used in the registry workflow. It combines optical character recognition and language model reasoning for text embedded in images. Its image defacing uses a mask to preserve anatomical detail, and its date mechanism applies an offset while keeping intervals intact. The platform can run customer models through a local plugin.

INTContour’s segmentation models are convolutional neural networks trained with expert contours. The CuratAI registry workflow gives the model size and hardware requirements without identifying the weight release used.

BB on Model Supply Chain DisclosureSubstantial partial disclosure, or a chain that is structurally short: an in house build, a cleared model that cannot be quietly swapped, or a deployment where the transfer does not occur at all. Naming the model provider exits the band below into this one; the axis rises from here on the completeness of the party list and on the terms that govern data once it arrives.
Vendor Published

CuratAI runs its application, database, language model and customer model runner inside the institution’s network. The software handles notes, images, dates and headers locally, and keeps the file that links research data back to patients on site. Under Carina’s privacy terms, the company collects data from installed software only with acknowledgment or permission. The platform accepts models supplied by the research team through its local plugin interface.

Signed project tokens permit collaborators to open a deidentified project. The institutional system manages any models a team brings, while the registry service identifies its own language model by size.

AA on Clinical and Operational EvidencePeer reviewed or independently evaluated performance, prospective and multi site where the claim requires it, with the method available to read. The grade describes the strength of the evidence, not its direction: a rigorous study that found no benefit grades by its design, and the note leads with what it found.
Peer Reviewed Publication

University of Pennsylvania researchers tested four defacing methods on images from 88 brain patients and 97 head and neck patients. The evaluation used facial recognition to measure reidentification risk and compared structure volumes and intensity before and after defacing. Carina’s method preserved structure volumes, while mean CT intensity in the eyes changed by a median of 24.5%.

At Mayo Clinic Arizona, a separate INTContour research evaluation used 100 local prostate cases for retraining and 115 test cases. Six radiation oncologists and two residents rated the resulting contours blind to their source. The AI contours met or exceeded manual contours in more than half of cases across the structures tested.

BB on AI Safety and PHI StewardshipCategorical commitments are published, such as no training on customer data, without the retention schedule behind them.
Vendor Published

CuratAI processes source records, images and text inside the institution. It strips identifiers from image headers and burned in text and uses a patient specific date offset to preserve intervals. Logs and the file linking research records back to patients remain on local storage. Cross institution sharing requires explicit action and verified deidentification before an artifact can leave. The product allows a research group to train its own model locally against the resulting cohort. Carina’s commitments keep patient data away from its own systems during ordinary use, while the institution manages how long it keeps the source and processed records.

Regulatory and Compliance
BB on HIPAA and BAA PostureBusiness associate status is stated and supported by a substantive privacy document, with the agreement or its scope not fully published. For a vendor outside the United States, an equivalent regime documented to this depth grades here. A vendor whose product does not process protected health information grades here too when it says so plainly and explains the scope, with a service privacy document behind it: stating a position a buyer can rely on is the posture this axis grades, and the band above is closed to it because there is no agreement to publish.
Vendor Published

CuratAI keeps the software, storage and patient data within the customer’s network, where the institution applies its HIPAA controls. Carina treats the local deployment as having no outbound protected health information. Its privacy terms extend to installed products and require customer permission before collecting data from their use. The software has roles for investigators, annotators and approvers and uses project access for sharing deidentified data.

Carina makes business associate agreements available through its compliance contact, depending on product and deployment. Its local model and audit logs process the data under the institution’s control.

DD on Security Certifications and Trust CenterControls are asserted with nothing independent behind them, or nothing is published. Read the note before concluding anything: this is the grade most often corrected on a second pass, because assurance material frequently sits on a parent domain or inside an old announcement rather than on the product pages.
Vendor Published

The clinical and research products install on infrastructure the customer controls, with no telemetry and no automatic updates over the internet. CuratAI logs each transformation and keeps both the audit trail and the identifying link file inside the network. Project sharing is scoped with signed tokens and gated on deidentification.

Carina walks institutional IT and compliance teams through architecture, controls and audit logs, and answers InfoSec questionnaires and supplies DICOM conformance statements on request. No SOC 2, ISO 27001 or HITRUST attestation and no penetration test is named for Carina's own operations, so security rests on the deployment design and the institution's controls.

DD on FDA and Regulatory StatusThe positioning is unclear or unsupported: clinical claims with no regulatory position stated, or language implying a status the databases do not carry. An open enforcement action that names the product also grades here, whatever the positioning: an FDA warning letter with no close out letter posted, or a consent decree in force. The note says which of the two applies, and the grade returns to the positioning bands when FDA closes the action.
Regulatory Filing

CuratAI prepares research data and cohorts for analysis. INTDose’s K213137 clearance covers independent Monte Carlo dose verification for trained radiation oncology personnel. INTContour’s K212274 covers initial segmentation for clinician review from CT and MRI in the listed anatomy, including male pelvis. Carina’s INTContour offer says its cleared models cover “120+ OARs and lymph node groups across CT, MRI, and PET/CT” and lists female pelvic structures in its available set. The clearance names CT and MRI and the male pelvis. Carina identifies custom training as research use and labels OncoAI, QuantBrain and NeuroStage for research.

BB on AI Governance and Bias DisclosureA governance framework with named process behind it, such as certification to an artificial intelligence management standard, or material written for a customer own review committee to evaluate the product with. A framework covering the vendor whole portfolio counts when its scope reaches this product; what it cannot supply is the product specific evaluation the band above asks for. Published results within the one group where the performance of this product is most at risk also sit here: evaluation on the question this axis asks, short of the comparison across groups the band above requires. A medical device clearance or certification, and the quality system behind it, does not reach this band on its own; it is graded under regulatory status. A regulator reviewed plan governing how the model may change does reach it.
Peer Reviewed Publication

CuratAI routes each field its local language model extracts by confidence. On the STAR neurovascular registry, 86% of fields landed at confidence 1 with about 89% accuracy and were accepted automatically, while 14% went to staff review. That validation, 29 patients and 170 fields against the site's REDCap record, is submitted for publication and covers one registry. Text deidentification was validated on the i2b2 2014 set of 514 discharge summaries.

No results compare the models across patient groups, sites or registries. A University of Pennsylvania study compared CuratAI's defacing with three other methods across CT, MRI, PET and dose maps and found it preserved organ volumes, and that defacing works by masking the face.

BB on AI Liability and RecourseA published falsifiable commitment, or a real correction route the affected person can exercise against the vendor. A published error rate with its method and denominator grades here. A statutory right that runs to the covered entity rather than to the vendor does not reach this band on its own: every other route here asks something of the vendor, and being located in a particular jurisdiction is not conduct.
Vendor Published

CuratAI records who edited a contour, when the change was made and what was altered, allowing a correction to be reversed. In a 29 patient STAR registry validation, submitted to Neurosurgery in 2026, the local model matched the REDCap reference at 87.7% across 170 evaluable fields, within 3.2 points of a cloud model. Confidence grouping routed the less certain fields to staff.

INTContour offers Dice, mean surface distance and Hausdorff checks against reference contours, and clinicians can edit the segmentation before use. Software terms for customers come with the product license. The public website terms govern access to the website and do not promise compensation for an erroneous contour or research field.

Integration and Deployment
BB on EHR and Interoperability DepthNamed systems with read access or one directional writing, or standards support with named deployments behind it.
Vendor Published

CuratAI receives data from PACS, EHR and pathology systems and can drive a batch pull with REDCap, an Excel file or a CSV export. It accepts DICOM, NIfTI, whole slide images, PDFs and clinical notes. The registry workflow turns notes into fields that can be checked against the REDCap source. Curated annotations can be exported as DICOM RT, NIfTI or DICOM SEG.

In radiation oncology, INTContour uses Eclipse treatment planning system scripting and automated DICOM transfers to receive a study and send its annotated structures back. The research connectors are described by system type.

AA on Deployment Model and Data ResidencyDeployment options, residency and tenant isolation are all documented, including where data rests and which processing crosses a border.
Vendor Published

CuratAI’s application, database, local language model and plugin runner install on a Windows workstation or Linux server inside the buyer’s network. The customer retains its patient data, identifying link file and processing logs on its own storage. Access is assigned to the research project and to the role of the staff member. There is no shared hosted tenant for identified data.

A collaborator at another institution receives a signed token limited to a deidentified project after the sending organization approves sharing. Cross institution access is limited to the material in the project, and the linking file and processing logs stay with the sending institution.

Commercial
DD on Commercial TransparencyNothing a buyer can establish before a sales conversation. A published pricing claim contradicted by evidence also grades here.
Vendor Published

Carina sells software through a sales engagement and offers a 30 minute walkthrough with its technical team, with demo access through its account portal. CuratAI installs on a Windows workstation or Linux server and supports local models and research workflow integration, and its registry model runs on a single 12 GB consumer graphics card, so hardware can come from what the institution already owns.

INTContour offers clinical segmentation for radiation oncology and separately identifies its model training tools as research features. Each software product comes with its own license agreement, and the purchase terms, the unit of charge and the price of a deployment come out of the sales conversation.

BB on Setting and Specialty CoverageCoverage is named with validation behind part of it.
Peer Reviewed Publication

CuratAI is used by academic medical centers preparing multimodal clinical research data. University of Colorado Anschutz uses it for data retrieval and processing in foundation model work. The University of Pennsylvania evaluated deidentification with 185 brain and head and neck cases. The registry engine was validated on the STAR neurovascular registry, and the same engine is offered for GWTG Stroke, oncology and custom institutional registries.

The radiation oncology line adds segmentation across four regions and dose verification for treatment planning quality assurance. At Mayo Clinic Arizona, local retraining addressed anatomy on the prostate protocol in an evaluation of 115 test cases. QuantBrain, OncoAI and NeuroStage are labeled for research use.

Alternatives

Alternatives to Carina AI

Other products that do the same kind of work as Carina AI, and what each one does.

Lifen DataLab is the multicenter research product from Paris based Lifen, the document platform used by more than 800 French healthcare facilities.

Mendel, based in San Jose and backed by Oak HC/FT and DCM, sells Hypercube, a platform that reads unstructured patient records for chart review, cohort building and clinical trial prescreening.

Verantos, Inc. of Menlo Park, California, led by CEO Dan Riskin and president Anand Shroff, sells real world evidence products and services to biopharma, for R&D, clinical development, regulatory, safety and post marketing work.

Therapixel sells MammoScreen to hospitals, screening programs and breast imaging practices. The software reads compatible 2D mammograms, 3D breast tomosynthesis and available prior examinations.

Aignostics builds foundation models for computational pathology and sells them, and applications built on them, to biopharmaceutical companies for target discovery, translational research, clinical trials and companion diagnostic development, and to pathology laboratories under research use terms.

Quibim, a Valencia company named for quantitative imaging biomarkers in medicine, turns medical images into measurements and predictions and sells AI software as a medical device to hospitals alongside a platform and services for biopharma, after a commercial launch in 2021.

Commercial

Pricing

Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.

Entry Price Pricing Basis BAA Tier Implementation Source
Product license by quote
Carina sells each product under its own software license. It sets up demo access and a 30 minute technical walkthrough. Carina provides BAA information for specific deployments through its compliance team. The software runs on customer infrastructure. Deployment and integration are scoped with the product license. Vendor Published

CuratAI runs within the research institution. INTContour and INTDose are also available under their own product agreements.

Contact us

Found a vendor we missed? Have feedback on the index? We’d love to hear from you.