Therapixel
Therapixel sells MammoScreen to hospitals, screening programs and breast imaging practices. The software reads compatible 2D mammograms, 3D breast tomosynthesis and available prior examinations. It marks areas such as calcifications or masses and assigns a suspicion score from 1 to 10 at the finding, breast and exam levels. A precheck presents image quality and patient information before interpretation. During reporting a physician selects the findings to include and chooses the final assessment. The software fills structured fields such as lesion location, depth and distance to the nipple.
MammoScreen BD assigns breast density using the four BI RADS categories and is available in the same installation. In the US, the FDA clearances cover concurrent reading and reporting and a separate adjunctive breast density assessment for asymptomatic women 40 and older. The French offer also includes a breast cancer risk estimate at 2 or 5 years under its CE marked product release.
The hosted configuration takes images from the customer's imaging system through a local gateway. The gateway removes identifiers and encrypts the images before sending them for computation, and routes the result back into the screening workflow. An installation at the customer's facility is also available. Mayo Clinic procured radiology licenses, and Groupe Imagerie Cardinet made MammoScreen available to radiologists across 30 sites in France.
Capability Axes
An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read
MammoScreen reads screening mammograms and marks and scores findings suspicious for breast cancer. The calculation combines information from compatible digital mammography, tomosynthesis and prior examinations. Deep learning modules recognize soft tissue lesions and calcifications using training cases with biopsy confirmation where appropriate. The algorithm assigns a suspicion score to each finding and carries the highest relevant score through to the breast and exam. A related module estimates tissue density. The software is sold for these learned interpretations, and the viewer integration and report fields use the findings and measurements those models produce.
A radiologist remains the decision maker for every screening exam and can inspect any proposed finding. The case precheck flags concerns with image quality. The intended use excludes reliance on poor images and nonstandard views, even if software happens to generate a result. The score display highlights more suspicious cases and initially hides marks on scores 1 through 4.
The physician can show those marks, choose which findings to include, select a final BI RADS category and submit the report. An uncertain or high suspicion score still leads to a physician's review within the same workflow.
Therapixel builds separate deep learning components for soft tissue findings and calcifications. The models train on annotated mammograms, including biopsy confirmed cancers or normal tissue, with a development collection of more than 1 million exams from 15 US and European sites. Testing uses data sources held out from training and work on newer versions tests added combinations of current and prior images.
Scope of changes is controlled by the versioned submissions and by the plan for adding imaging systems under version 4. The detector and density models are identified by their training and function, with architecture details reserved for the device design.
The cloud version receives mammograms from a virtual gateway that strips identifiers and encrypts the image transfer. Therapixel runs its own detection and scoring models and delivers the result back through the gateway. The software can also be installed at the facility. The image sources include current screening studies, compatible earlier exams and optional context gathered through the reporting system. RamSoft offers the model workflow inside its imaging platforms. The cloud implementation identifies the model maker without enumerating all infrastructure processors or their data handling terms.
A multireader study of MammoScreen's combined 2D, 3D and prior exam system, published in the Journal of Breast Imaging in 2025 with radiologists from Cooper Medical School of Rowan University and SSL Imaging, read 90 cancer proven and 150 negative cases unaided and aided. AUC rose 7.4%, readers found 8% more cancers and reading time fell 24%.
The MammoScreen 3 filing reports the same design with 23 radiologists, sensitivity rising from 70.6% to 79.3% and specificity from 81.5% to 83.6%, beside a standalone test on 7,544 exams from 4,429 women at three US centers. An earlier Therapixel model was evaluated independently in the DREAM challenge (JAMA Network Open, 2020).
A gateway on the customer's premises removes identifying information from DICOM images before encrypted transfer to the hosted model. The service deletes the images when the practice receives the output, typically after a few minutes. The report returns to the gateway for redistribution into the practice's screening software. European health data it handles is confined to the European Economic Area. The training collection includes annotated exams from US and European institutions. The service does not commit to a rule governing future model training on patient images retained under a separate arrangement.
The US workflow keeps patient identifiers in the practice and sends encrypted, deidentified images for model processing. Therapixel operates as a HIPAA compliant company on a HIPAA compliant cloud host, de identifying every DICOM image that leaves a practice and deleting cloud images once the output report is delivered.
Its European service uses a certified health data host and commits the personal health data it processes to the European Economic Area under GDPR and French data protection law. Business associate terms for an individual US installation are agreed separately, with no agreement or tier published.
Therapixel holds ISO 27001 for its information security management system, covering both the operation of MammoScreen and the research that develops it. The cloud workflow encrypts DICOM images before transfer, removes identifiers at the installed gateway and deletes the processed images after the output returns, a round trip that usually takes under two minutes. Its French offer runs on certified health data hosting under HDS. An on premises installation keeps images inside the facility altogether. The current certificate, its version and its renewal dates come from the company on request, with no trust portal.
The US device line began with 2D screening under K192854 (March 2020) and added digital breast tomosynthesis under K211541 (November 2021). K240301 (August 2024), K243679 (July 2025) and K260714 (June 2026) cover MammoScreen 3 through 5 as concurrent reading aids with compatible prior images, version 5 on supported GE and Hologic configurations, with interpretation left to the physician.
MammoScreen BD clearances K241561 and K243685 cover adjunctive BI RADS density assessment for asymptomatic screening patients 40 and older. The 2 or 5 year cancer risk estimate is sold only in France, under a CE marked release, and no US clearance covers it.
The MammoScreen 3 model was evaluated on 7,544 exams from 4,429 people screened in three US centers, and its results were analyzed by density, race and other clinical characteristics. Standalone sensitivity was 95.8% for density category A and 81.6% for category D at the study threshold. The same filing gives separate performance results for White, Black and Asian patients. MammoScreen 4 and MammoScreen BD have FDA authorized change plans with tests for acquisition system modifications. Version 5 also tests additional combinations of current and prior images on data from sources held out during training.
The viewer shows what the model marked and links its score to the relevant image location. A radiologist can select or exclude findings from the preliminary report and independently chooses the final assessment. The device evaluation gives measured differences in sensitivity and specificity for assisted and unassisted reads, with confidence intervals, and reports standalone performance by breast density and race.
Image quality alerts give a reason to look again before relying on a mark or score, and Therapixel warns users that soft tissue lesions or calcifications can be missed or undervalued. A correction to an interpretation is made in the clinical workflow, and any remedy for a missed or incorrect mark rests on the customer's own license agreement.
The imaging modality or PACS sends the study to a MammoScreen gateway and receives the analyzed output for the reading workflow. The software supports DICOM structured reports and secondary capture. It can collect patient history through an interface using HL7, FHIR or APIs and populate reporting fields with selected findings. RamSoft embeds the product in its PowerServer and OmegaAI imaging platforms. The reading workflow runs through the PACS and the gateway, and no customer is named exchanging history and reports with a major hospital EHR in production.
MammoScreen can run in a hosted configuration or at the practice. In the hosted configuration a virtual gateway removes patient identifiers and sends encrypted images to compute the results. The gateway returns those results to the practice. Therapixel commits European personal health data it processes to storage in the European Economic Area, with no transfers of such data to countries beyond that region. Its French service uses certified health data hosting. The US integration keeps identifying patient information in the facility. The cloud service's specific tenant separation arrangements are contract details.
The subscription charges for each mammogram it successfully processes and includes version upgrades. MammoScreen is sold to practices in the United States and Europe. Practices can arrange an evaluation on their own exams or a limited pilot with remote setup and training. The ROI calculator uses annual screening volume to estimate time savings, revenue and additional detections based on assumptions. The amount due for each successfully processed mammogram is set through the commercial order.
MammoScreen is used for screening mammography in hospital radiology and breast imaging practices, with separate models for lesion scoring and density. The US indication covers screening FFDM and DBT from compatible GE and Hologic systems and excludes synthetic 2D images, women with prior breast surgery, implants or internal markers, and women with a pacemaker. The density device serves asymptomatic screening patients 40 and older.
The detection model was tested with breast imaging specialists and general radiologists across 240 paired current and prior cases. Mayo Clinic licensed the product for its radiology workflow, and Groupe Imagerie Cardinet offers it to radiologists at 30 French sites. The French risk estimate has no measured result behind it.
Alternatives to Therapixel
Other products that do the same kind of work as Therapixel, and what each one does.
Genius AI Detection is the breast imaging AI software line of Hologic, Inc. of Marlborough, Massachusetts, licensed to breast imaging buyers separately from Hologic's wider diagnostics, surgical and skeletal businesses.
ScreenPoint Medical, founded in 2014 by Nico Karssemeijer and Sir Michael Brady and based in Nijmegen in the Netherlands, makes Transpara, breast AI for mammography and tomosynthesis.
Clairity Breast estimates a woman's probability of being diagnosed with breast cancer within five years of a bilateral screening mammogram.
CureMetrix, a San Diego company founded in 2014, sells AI software that reads screening mammograms for breast imaging centers, mammography practices and hospital radiology departments.
Incepto sells a platform for running imaging AI in hospital radiology departments, imaging centers and radiology groups.
Koios Medical, based in New York, sells Koios DS, AI decision support software for breast and thyroid ultrasound that it calls Smart Ultrasound.
Pricing
Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.
| Entry Price | Pricing Basis | BAA Tier | Implementation | Source |
|---|---|---|---|---|
|
Quote per successfully processed mammogram
|
Subscription billed by successfully processed mammograms. Software upgrades are included. | The US workflow is offered with HIPAA compliance and keeps identifiers at the practice. European health data processing follows GDPR and the European Economic Area commitment. | A limited pilot can include remote installation and training. A practice can also request an evaluation with its own cases. | Vendor Published |
The ROI calculator estimates time, detections and revenue using annual screening volume. The license rate is set in the commercial order.