FaceHeart
FaceHeart sells its Vitals software development kit to telehealth services, digital health developers, insurers and device makers. A camera scan captures changes in reflected light from the face. Computer vision locates the subject, and signal processing and deep learning help extract usable measurements as lighting and movement vary. The usual scan lasts 50 seconds. An organization can embed the kit in a phone or desktop application, use it on an embedded device or integrate the browser version. The Edge SDK performs the measurement locally without an internet connection and retains no camera images.
The US pulse rate clearance covers contactless spot measurements in adults who stay still and do not have known or suspected arrhythmias. A later clearance covers respiratory rate spot checks using chest wall motion in adults under professional supervision. It applies in clinical or home settings on compatible devices. The product family also estimates blood pressure, oxygen saturation and heart rate variability and flags atrial fibrillation, none of them under a US clearance.
Grupo Red Salud integrated the SDK into Salud Selfie so users could capture readings for remote review by its care team. Emagine Solutions Technology incorporated camera based measurements into The Journey Pregnancy for tracking trends. The license is sold under a separate agreement that sets the product version and its permitted use.
Capability Axes
An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read
The FaceHeart Vitals SDK turns ordinary camera video into a set of physiological measurements. Computer vision tracks the subject and remote photoplethysmography isolates slight variations of facial color. The technology uses deep learning to recover a usable signal under changes in light and movement. A respiratory version follows a region of the chest and measures cycles of chest movement. The product is licensed as the measurement layer a partner embeds in an application or device. Remove the learned camera signal processing and the SDK cannot deliver the contactless measurements that the buyer licenses it to produce.
The pulse rate kit takes a spot reading with the subject and camera stationary. Its scan reports a missing face or motion when the camera cannot acquire a usable view. The implementation instructions for mobile devices with accelerometers call for using the measurement only while the camera is stationary. The respiratory kit counts chest wall movements in a well lit setting and requires professional supervision or instruction. Each integrator sets how readings are displayed and sent onward. The software's instructions leave the routing of unusual readings to the integrating application.
A camera stream supplies the input for face detection, tracking and extraction of small skin color changes related to blood flow. The SDK uses deep learning to compensate for changes in lighting and motion. The respiratory rate variant finds the chest region and counts breathing cycles from changes in that region. FaceHeart has collected more than 400 million data points from more than 36,000 testers as of 2026 for its research and validation. The model details stop short of connecting a named training cohort and release history to each SDK version.
The Vitals Edge SDK runs the measurement on the end device without internet access or storing the captured images. FaceHeart develops the underlying video based measurement technology. Developers embed the kit in an application or device and the customer controls the resulting readings. A browser version can also run with hosted processing. The local kit can complete the scan without sending camera input to an external processor. The hosted mode does not define which organizations operate its measurement service or what contractual controls apply to their access.
In a regulatory study of 527 adults, the pulse rate kit was compared with a Philips MX100 ECG across five camera configurations. An average of 93.8% of measurements fell within 3 beats per minute of the reference across those configurations. A separate study of 420 adults in Taiwan and the United States compared respiratory rate readings with a reference monitor and found an overall root mean square error of 1.2 breaths per minute. Grupo Red Salud and Emagine Solutions Technology integrated the SDK into care applications. Their results do not quantify a change in patient outcomes.
The Edge SDK processes the camera input on the device and completes a measurement without storing the frames. FaceHeart commits that it does not store or access the SDK user's health data. The customer controls the use and storage of the measurements it receives through its integration. A browser version is also offered, and individual agreements govern processing, audit, retention and incident procedures in customer deployments. The product commitment covers storage and access but does not establish a training policy or retention period for processing under a hosted deployment.
Customer applications collect facial signals and receive the derived vital signs. The local SDK processes camera input on the device and the integrating organization controls the measurement record. FaceHeart's site terms direct businesses to a separate customer agreement for data protection, processing roles and cross border transfers. Those site terms cover visits and inquiries.
They do not serve as a business associate agreement for the health information handled in a software deployment. Each integrating organization determines how its application collects and uses readings.
The Edge SDK runs the scan without an internet connection and retains no images. The customer controls the system that receives the measurement. The pulse rate submission included software cybersecurity testing and vulnerability analysis. FaceHeart also holds ISO 13485 for its medical device software quality system. The customer agreements establish security and incident responsibilities for particular integrations. The technical submission checks the software for vulnerabilities but does not establish an independent security assessment for the organization that operates the hosted service.
FDA clearance K223622 (September 2023) covers camera based pulse rate spot checks in stationary adults 18 and older without known or suspected arrhythmias. K243966 (April 2025) covers prescription respiratory rate spot checks from chest wall motion in adults under professional supervision, in clinical or home settings, from 5 to 36 breaths per minute.
Both exclude continuous monitoring and critical care, while the telehealth page says FaceHeart Vitals "enables continuous vital sign monitoring". Blood pressure, oxygen saturation, heart rate variability, atrial fibrillation and a 10 year cardiovascular risk score are marketed with no clearance, and the April 2025 release calls the SDK FDA cleared beside blood pressure, oxygen saturation and heart rate variability.
The pulse rate study enrolled people across the Fitzpatrick skin type scale, including 83 participants in types V and VI, and reports agreement by camera configuration. The respiratory rate study of 420 adults in Taiwan and the United States reports error by breathing rate band on five cameras, with the largest error at 5 to 8 breaths per minute.
It found no significant differences by sex, age or body mass and no major issues in cardiovascular, neurological or pulmonary patients, without giving error figures for those groups. The respiratory filing describes chest motion analysis with no learned method named, and the pulse results are not broken out by skin type.
The pulse rate and respiratory rate kits provide warnings or positioning instructions for conditions that undermine a reading. A comparison against ECG in 527 adults quantifies pulse measurement errors for individual cameras. Under large movements the pulse rate kit's mean absolute error in internal testing ranged from 11.77 to 42.06 beats per minute. The respiratory instructions require professional oversight and the integrator controls how users see or repeat results. The written agreement for a deployment governs product liability. The SDK provides a way to take another reading under supported conditions.
FaceHeart integrates its measurement toolkit into existing applications for iOS, Android, desktop and web, and the SDK hands results to the integrating application's own workflow and data handling. In Grupo Red Salud's Salud Selfie deployment in Peru, APIs carry measurements into the health team's remote dashboards. Emagine Solutions Technology uses the scans in The Journey Pregnancy so expectant mothers can follow blood pressure trends without home equipment. Readings reach a hospital record only through the integrator's own work, with no connector to a named EHR.
The Edge SDK runs the measurement locally on supported mobile devices, computers and embedded hardware. It keeps images out of storage and does not need internet access for the scan. Software for browsers can run with hosted processing. The customer controls the resulting health data and chooses terms for storage, processing roles and cross border transfers in its service agreement. The hosted offer places regional storage and transfer obligations in the organization's individual deployment agreement.
The SDK is licensed through a separate written agreement with the healthcare organization, software developer, distributor or other customer. A business can request a demonstration and discuss its target devices, operating systems and integration. Work under a pilot, a hosted service or a production deployment is set in the order and associated documents. The sale covers software use and can include deployment services. The quote and contract determine the unit used to calculate charges for the installation.
The cleared pulse rate kit supports spot checks in adults on compatible phones, computers and webcams. The respiratory version also serves home use under healthcare professional supervision. The respective regulatory studies enrolled 527 and 420 adults and compared outputs with clinical monitors. The SDK has been incorporated in a telehealth service in Peru and in a US pregnancy application for tracking trends. Other deployments target insurance, employee wellness and embedded devices. The cleared configurations give clinicians and partner developers separate scopes for pulse and respiration checks.
Alternatives to FaceHeart
Other products that do the same kind of work as FaceHeart, and what each one does.
Upvio sells Vitals AI to telehealth providers, pharmacies, insurers and workplace wellness programs. The software uses a phone, tablet or computer camera to estimate physiological signals from a face scan that takes about 30 seconds.
Biobeat sells wearable vital sign monitors and a cloud platform for hospitals, long term care and home programs.
Exer AI sells movement assessment and monitoring software for orthopedic, rehabilitation and other healthcare practices.
Vivalink sells the sensing and data layer that other organizations build monitoring products on.
Dozee, built by Turtle Shell Technologies in Bengaluru, sells contactless patient monitoring to hospitals, skilled nursing facilities and remote care providers.
Impilo runs the physical and software sides of remote care for digital health companies, providers, payers and device makers.
Pricing
Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.
| Entry Price | Pricing Basis | BAA Tier | Implementation | Source |
|---|---|---|---|---|
|
Enterprise agreement
|
FaceHeart licenses the SDK and related services through a written customer order or agreement. | The deployment agreement governs processing roles and health data obligations. | The order or statement of work sets the scope of integration, pilot and production deployment work. | Vendor Published |
Eligible buyers can request a demonstration. The commercial order sets the rate and the unit used to bill the organization.