Radiology & Imaging AI
A

AmCad BioMed

AmCad BioMed makes AI software that reads ultrasound images, led by AmCAD-UT for thyroid nodules. Loaded with a B mode thyroid image from any ultrasound machine, AmCAD-UT outlines the nodule, color codes its echogenicity, shape, margins and calcifications, quantifies how strongly each feature points to malignancy, scores it under eight TI-RADS systems the clinician can choose between, and drafts a report for review and export. It runs on Windows for DICOM files and PACS workflows and on Android with handheld ultrasound probes in real time. FDA cleared AmCAD-UT as computer aided detection software in September 2021 (K203555), for user selected nodules larger than 1 cm with an AI suggested outline, after earlier clearances for the predecessor version and for AmCAD-UO, AmCAD-US and AmCAD-UV.

AmCAD-UO turns a ten minute awake ultrasound scan of the upper airway, captured with a laser guided robotic arm, into an instant risk result for moderate to severe obstructive sleep apnea and maps likely collapse sites at the velum, oropharynx, tongue base and epiglottis; AmCad reports 83.9% accuracy against sleep study diagnoses. AmCAD-UB applies BI-RADS terms to breast ultrasound, and AmCAD-US measures soft tissue texture, used in research on fatty liver and fibrosis. Independent studies of AmCAD-UT include a four hospital prospective study of 565 nodules in China and work at Germans Trias i Pujol in Spain and the Federal University of São Paulo.

AmCad BioMed Corporation was founded in 2008, is listed on the Taipei Exchange under ticker 4188 and is led by CEO Yi-Li Lee. It cites multiple FDA and CE certifications, and it exhibits at MEDICA in Düsseldorf and Healthcare Expo Taiwan.

AI Health Index verifiedNovember 23, 2026
Compare AmCad BioMed with other vendors
Founded
2008
Headquarters
Taipei, Taiwan
Categories
radiology-and-imaging-ai
Indexed Products
AmCAD-UT thyroid nodule assessment, AmCAD-UO obstructive sleep apnea assessment, AmCAD-UB breast ultrasound, AmCAD-US tissue analysis
Buyer Segments
Radiology Practices, Endocrinology Clinics, Sleep and ENT Clinics, Hospitals
Assessment

Capability Axes

An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read

AI Capability
BB on AI CentralityThe model is the engine of a core module. The platform carries other value, but this capability does not exist without it.
Regulatory Filing

Image analysis is what AmCad sells, and learned components drive its core outputs: the K203555 clearance of September 2021 adds an AI contouring algorithm that outlines a user selected thyroid nodule, AmCAD-UT quantifies a malignancy level from sonographic features with patented algorithms, and AmCAD-UO estimates the probability of moderate to severe sleep apnea from upper airway images. Other parts carry value without a model.

AmCAD-US measures tissue texture with backscatter statistics, a parametric method, the predecessor AmCAD-UT Detection 2.2 quantified features on outlines the user drew, and AmCAD-UO's laser guided robotic arm standardizes image capture between sessions.

BB on Autonomy and Oversight ModelThe oversight structure is described and one part is missing, commonly the threshold at which the system stops or what happens after it is wrong.
Regulatory Filing

The cleared workflow puts the physician first: under K203555, the physician reviews the ultrasound images, selects the nodule and accepts or redraws the AI's suggested outline before AmCAD-UT quantifies its features, and the device is for prescription use on nodules larger than 1 cm that need a biopsy decision.

AmCAD-UT is sold on a faster flow, in which nodules are identified and outlined automatically as soon as the image loads with no manual tracing, a TI-RADS score appears within seconds, and a report is created ready for review and export. What the software does when it misses a nodule, and any confidence below which it withholds a score, are not given.

CC on Model and Technology TransparencyThe architecture is described in general terms with nothing identified. Proprietary is asserted rather than explained.
Vendor Published

The method is described by function: AmCAD-UT extracts and quantifies sonographic features with patented algorithms and patented visualization, supports eight TI-RADS systems, and in its cleared version adds an AI contouring algorithm; AmCAD-UB flags suspicious areas during scanning with BI-RADS lexicons; AmCAD-UO analyzes images of the velum, oropharynx, tongue base and epiglottis; and AmCAD-US maps the statistical distribution of backscattered ultrasound signals, a method set out in published research.

No model type, training data set, image sources or update practice is given for the AI parts, and K203555 treated the contouring algorithm as a minor change from version 2.2 with the model itself never described.

BB on Model Supply Chain DisclosureSubstantial partial disclosure, or a chain that is structurally short: an in house build, a cleared model that cannot be quietly swapped, or a deployment where the transfer does not occur at all. Naming the model provider exits the band below into this one; the axis rises from here on the completeness of the party list and on the terms that govern data once it arrives.
Regulatory Filing

Algorithms are built in house and shipped as installed software: AmCAD-UT is cleared as a Windows based device analyzing images from FDA cleared ultrasound systems and is also sold for DICOM files on a PC and on Android with handheld probes, while AmCAD-UB flags lesions in real time during scanning and generates DICOM ready reports. No outside model provider, cloud host or subprocessor is named, and the cleared AmCAD-UT algorithm cannot change without a new FDA submission. Whether the Android version, AmCAD-UB or AmCAD-UO's instant risk report sends images to a server, and if so to whose, is not addressed.

BB on Clinical and Operational EvidenceNamed deployments with dated outcome figures and enough method to test them, or published research short of independent validation.
Peer Reviewed Publication

Independent studies of AmCAD-UT are substantial. A multicenter prospective study at four Chinese hospitals, Ultrasound in Medicine and Biology (2021), enrolled 494 patients with 565 nodules confirmed by pathology: the software's sensitivity of 90.51% matched a senior radiologist's, its specificity of 49.63% trailed all three readers, and a junior radiologist's area under the curve rose from 0.739 to 0.816 with it.

Germans Trias i Pujol in Spain and the Federal University of São Paulo published further studies, and a 2026 prospective study in Shanghai tested it in active surveillance. AmCad sells AmCAD-UT on "AI raises accuracy for readers of all experience levels", while the prospective study tested it only with the junior reader.

DD on AI Safety and PHI StewardshipNothing published on how protected information moves through the system.
Vendor Published

No statement covers patient images or reports. AmCad has no privacy policy, terms of use or data handling statement, and nothing says whether AmCAD-UT on Android, AmCAD-UO's instant risk result or the drafted reports leave the device, how long images are kept, or whether customer images train future versions. The cleared AmCAD-UT runs as Windows software on images the site already holds, which keeps that version's data local by design.

AmCAD-UO returns its risk result during a ten minute awake scan captured by a robotic arm, with no word on where those airway images go afterward, and no guardrail or error handling for the AI outline is described beyond the physician's review of each nodule.

Regulatory and Compliance
DD on HIPAA and BAA PostureNo statement of status and no privacy document that reaches the product. Both halves are absent at this grade: a service level privacy document on its own lifts a vendor to the band above even where no status is stated. A website privacy notice, including one that says it does not cover customer data, does not reach the product, so a vendor whose only document is that notice and who states no status grades here.
Vendor Published

HIPAA is never mentioned, and no privacy document reaches the products. AmCad sells FDA cleared software for US clinical use, yet it offers no business associate position, data processing terms or privacy notice of any kind, and the contact form collecting professional emails is the only data collection described.

For the installed Windows version of AmCAD-UT, patient images stay on the customer's machine under the cleared design, and no statement says whether AmCad ever receives them, for support or otherwise. The Android and handheld versions, AmCAD-UB's real time lesion flagging and AmCAD-UO's instant reports have no data statement either.

DD on Security Certifications and Trust CenterControls are asserted with nothing independent behind them, or nothing is published. Read the note before concluding anything: this is the grade most often corrected on a second pass, because assurance material frequently sits on a parent domain or inside an old announcement rather than on the product pages.
Vendor Published

No security certification, audit or penetration test is named. AmCad's "multiple FDA and CE certifications" are device clearances and marks, and the K203555 file records documented design, verification and validation processes with a hazard risk assessment, a quality process with no outside security check named.

Nothing covers encryption, access control, user authentication or patching for the Windows and Android applications, or how a hospital's security team would review software that opens DICOM files from any ultrasound machine and connects to PACS. No security contact or vulnerability disclosure route is listed beside the marketing email and Taipei phone number.

BB on FDA and Regulatory StatusThe pathway is stated and in progress, or a clearance is named without the vintage and scope a buyer needs to match it to the product on offer. A product outside device regulation also sits here when the vendor publishes what it is for and in what setting and the product on offer matches, or names another regime it works under, such as a registration outside the United States. A general clause saying the service is not medical advice does not reach this band.
Regulatory Filing

AmCAD-UT holds K203555 (September 8, 2021, product code QIH), cleared as Windows based computer aided detection for user selected thyroid nodules larger than 1 cm, with an AI suggested outline after the physician's initial review. It is marketed past that indication: nodules identified and outlined "as soon as the image is loaded", TI-RADS scoring, malignancy quantification and a real time assistant on Android handhelds, none named in the indication.

AmCAD-UO holds K180867 (December 2018), AmCAD-US K162574 and AmCAD-UV K170069 (2017), while AmCAD-UB, sold with BI-RADS guidance, has no FDA clearance. AmCad cites multiple FDA and CE certifications for the company without numbers.

BB on AI Governance and Bias DisclosureA governance framework with named process behind it, such as certification to an artificial intelligence management standard, or material written for a customer own review committee to evaluate the product with. A framework covering the vendor whole portfolio counts when its scope reaches this product; what it cannot supply is the product specific evaluation the band above asks for. Published results within the one group where the performance of this product is most at risk also sit here: evaluation on the question this axis asks, short of the comparison across groups the band above requires. A medical device clearance or certification, and the quality system behind it, does not reach this band on its own; it is graded under regulatory status. A regulator reviewed plan governing how the model may change does reach it.
Peer Reviewed Publication

Performance has been tested in the cases most likely to fail. Indeterminate nodules, up to 30% of cases by AmCad's count, are where AmCAD-UT is sold hardest, and Reverter and colleagues in the European Thyroid Journal (2022) compared it with five observers on indeterminate images: accuracy dropped 4.2% on the 43 nodules readers disagreed about, against 19.9% for the experts.

A 2026 Head and Neck study of 150 nodules measured repeatability, with kappa from 0.49 to 0.98 between sessions and lowest agreement on shape. No results are compared across age, sex, nodule size, scanner make or populations outside Asia and Europe.

BB on AI Liability and RecourseA published falsifiable commitment, or a real correction route the affected person can exercise against the vendor. A published error rate with its method and denominator grades here. A statutory right that runs to the covered entity rather than to the vendor does not reach this band on its own: every other route here asks something of the vendor, and being located in a particular jurisdiction is not conduct.
Peer Reviewed Publication

Error rates for AmCAD-UT come from independent studies. The four hospital prospective study in Ultrasound in Medicine and Biology (2021) measured the software alone on 565 pathology confirmed nodules from 494 patients, at 90.51% sensitivity and 49.63% specificity, and the European Thyroid Journal study (2022) reported 74.2% accuracy, 87.5% sensitivity and 49.4% specificity on 37 concordant indeterminate nodules, with a further 43 difficult ones. Both describe the version in use at the time. No warranty, indemnity or remedy for a wrong output is offered, and AmCad sells with no terms of use or sale.

Integration and Deployment
CC on EHR and Interoperability DepthIntegration is claimed through standards or a middleware layer with no system named and nothing to verify.
Vendor Published

Integration runs through imaging standards: AmCAD-UT analyzes DICOM files from any ultrasound machine on a PC and is described as PACS compatible, the cleared version takes images acquired from FDA cleared ultrasound systems, reports are exported once reviewed, and AmCAD-UB generates DICOM ready reports.

No PACS, ultrasound vendor, EHR or reporting system is named as a partner, no DICOM structured report or HL7 output is described, and no site is named where results flow into a patient record. The Android version works directly with handheld probes, again with no named device maker, and AmCAD-UO's results stay with its own scanning station.

BB on Deployment Model and Data ResidencyOptions and residency are stated with isolation or the processing path left open.
Regulatory Filing

Installed software is the delivery model: AmCAD-UT is cleared under K203555 as a Windows based device and is also sold in an Android version for handheld ultrasound and for DICOM analysis on a PC, so images and results stay on the customer's own machines in the cleared form. AmCAD-UO pairs software with a laser guided robotic arm at the point of care, and AmCAD-UB works during scanning.

No cloud option, hosting provider or remote support access is described, and nothing says whether the Android app, AmCAD-UB or AmCAD-UO's instant report calls a server, which leaves the storage path for those versions unknown.

Commercial
DD on Commercial TransparencyNothing a buyer can establish before a sales conversation. A published pricing claim contradicted by evidence also grades here.
Vendor Published

Inquiries go through a contact form that asks for job title, company, country and the disease area of interest: OSA, breast, thyroid, tissue analysis or other ultrasound AI, with collaboration invited. No price, license model, unit of charge, distributor or route to buy appears for any product, and nothing indicates whether AmCAD-UT is licensed per device, per seat or per study.

AmCAD-UT runs on ultrasound machines and handheld probes the customer already owns, analyzing DICOM files from any machine, so no imaging hardware is needed for thyroid use, while AmCAD-UO's robotic arm adds hardware with no stated purchase or lease terms.

BB on Setting and Specialty CoverageCoverage is named with validation behind part of it.
Peer Reviewed Publication

Four conditions define the range: thyroid nodules for radiology and endocrinology, obstructive sleep apnea for sleep and ENT clinics, breast ultrasound screening, and soft tissue analysis offered for liver fibrosis, pediatric fatty liver and sleep apnea assessment.

Thyroid use is supported by prospective studies in China, Spain and Brazil, and AmCAD-UO by publications in JAMA Otolaryngology (2023), Sleep Medicine (2024) and Respiratory Medicine (2026) with 83.9% accuracy against sleep studies; AmCAD-US by liver studies in European Radiology (2021) and Ultrasonics (2024). AmCAD-UB has no study behind it, and the thyroid clearance limits AmCAD-UT to nodules larger than 1 cm needing a biopsy decision.

Alternatives

Alternatives to AmCad BioMed

Other products that do the same kind of work as AmCad BioMed, and what each one does.

Median Technologies sells eyonis LCS, AI software that reads low dose chest CT scans from lung cancer screening programs, finds pulmonary nodules, outlines them and sorts each into probably benign, suspicious or very suspicious with a malignancy score and the malignancy rate observed for…

DeepHealth is RadNet's digital health business and the entity that contracts RadNet's clinical AI and imaging informatics software to third party providers.

Optellum, based in Oxford with a US office in Houston, sells the Virtual Nodule Clinic, which identifies patients with pulmonary nodules, triages and tracks them, and scores malignancy risk with its Lung Cancer Prediction AI, a convolutional neural network applied to the CT scan.

Sonio makes prenatal ultrasound software for sonographers, maternal fetal medicine specialists and the obstetricians who read the scans, built as one platform with AI reading aids and a reporting and image management layer.

contextflow reads chest CT and shows the radiologist comparable cases alongside its findings.

Velacur ONE is a portable ultrasound elastography system from Sonic Incytes Medical Corp., founded in Vancouver in 2017.

Commercial

Pricing

Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.

Entry Price Pricing Basis BAA Tier Implementation Source
Not published
Sold through a contact form that routes inquiries by disease area. No price, license model or unit of charge is published for AmCAD-UT, AmCAD-UO, AmCAD-UB or AmCAD-US. No business associate agreement or HIPAA position is stated. Not published. AmCAD-UT installs on Windows for DICOM analysis or on Android with handheld probes; AmCAD-UO pairs software with a laser guided robotic arm. Vendor Published

Whether the software is licensed per device, per seat or per study, or bundled with ultrasound systems, is not stated.

Contact us

Found a vendor we missed? Have feedback on the index? We’d love to hear from you.