Radiology & Imaging AI
A

AI Metrics

AI Metrics is a Birmingham, Alabama radiology software company, launched in 2019 by Bob Jacobus, Paige Severino and radiologist Dr. Andrew Smith of the University of Alabama at Birmingham, that builds software for reading and reporting follow up imaging of patients with advanced cancer. A radiologist starts a follow up evaluation with the AI Metrics Co-Pilot, which reviews prior and preliminary CT or MRI reads and steps to the image of each tracked tumor in turn; the radiologist confirms the slice with one click, and single click algorithms measure the target, apply prior anatomic labels and calculate percent change under the selected response criteria, such as RECIST 1.1. Non target lesions are marked absent, present or progressed against prior exams, incidental findings are tracked, and a visual report with graphs, tables, key images and structured text builds in the background for oncologists. The FDA cleared AI Metrics in December 2020 (K202229) as picture archiving and communications software for CT and MR, with semi automatic lesion segmentation and labeling suggestions, as a workflow tool that does not directly generate a diagnosis. Installation is cloud based, loads images on top of the existing PACS viewer, signs users in with Active Directory and connects to worklists, PACS, RIS and EMR.

In a multi institutional comparative study with 24 radiologists and 20 oncologic providers reading 120 patients, AI Metrics cut average read time from 18.7 to 9.8 minutes, raised reporting accuracy from 73% to 91% and raised inter observer agreement from 46% to 73%. The company raised a $1.26 million bridge round in 2022, and Dr. Smith's liver fibrosis biomarker research won a Best of AJR award.

AI Health Index verifiedNovember 23, 2026
Compare AI Metrics with other vendors
Founded
2019
Headquarters
Birmingham, AL
Categories
radiology-and-imaging-ai
Indexed Products
AI Metrics, AI Metrics Co-Pilot
Buyer Segments
Radiology Practices, Hospitals and Health Systems, Oncology Teams
Assessment

Capability Axes

An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read

AI Capability
CC on AI CentralityArtificial intelligence is a feature layer on a product whose value stands without it. A learned component is a model whose parameters are estimated from data: machine learning, or a statistical model fitted to population data, including one then updated on the patient measurements. A fixed formula, a rule set, or a feedback controller that adjusts a dosing factor from the patient own readings is not one, however patient specific its output and whatever the vendor calls the adjustment.
Vendor Published

The AI is a layer on a workflow and reporting product. Single click algorithms automate tumor measurement and anatomic labeling, and the cleared device lists semi automatic lesion segmentation and labeling suggestions. Much of the product stands without them: the guided Co-Pilot sequence through tracked tumors, manual annotation tools, automatic tabulation of measurements, response calculation and the visual report.

An earlier version, eMASS, had guided workflows and annotation tools but no AI algorithms, and still reduced errors and halved evaluation time against manual methods, so the measurable gains predate the models.

BB on Autonomy and Oversight ModelThe oversight structure is described and one part is missing, commonly the threshold at which the system stops or what happens after it is wrong.
Regulatory Filing

A radiologist drives every step. The Co-Pilot steps to each tracked tumor, the radiologist confirms the right slice with a click before the system measures, labels and calculates change, and non target lesions are assessed by the radiologist against priors as absent, present or progressed.

As cleared, the product provides information interpreted by a trained professional, does not directly generate any diagnosis or potential findings, and leaves the diagnosis with the medical professional, and manual annotation tools sit beside the automated ones. The report builds in the background, sold as "virtually worry- and error-free", and no step shows the radiologist reviewing that report before it reaches the oncologist.

CC on Model and Technology TransparencyThe architecture is described in general terms with nothing identified. Proprietary is asserted rather than explained.
Regulatory Filing

The cleared software is a PACS for general purpose hardware on a native or virtualized Linux platform, with semi automatic segmentation and labeling suggestions, automatic measurement of each segmented lesion's longest and shortest diameters, automatic tabulation and structured reporting, and AI Metrics sells single click algorithms for tumor identification, measurement and labeling.

No model type, training set, version or update practice is named for those algorithms, and the components behind them stay in general terms. The report itself builds in the background while the radiologist reads, with graphs, tables, key images and structured text.

CC on Model Supply Chain DisclosureThe architecture is described and no model provider is named. Naming a hosting provider alone does not lift a record out of this band. Record the host in the note, because it matters for residency and breach scope, and grade on the model layer, which is the question this axis is named for.
Vendor Published

No party beyond AI Metrics appears in the data path. The product installs as a secure cloud based deployment, loads images on top of the customer's PACS viewer and connects to worklists, PACS, RIS and EMR, with deployment by internet software download and installation by trained AI Metrics technicians. Nothing names the cloud host or any subprocessor, or says whether the segmentation models are built in house or licensed. The 510(k) was filed through the Austin consultancy Innolitics, and the only privacy document refers to service providers in general terms for the website.

BB on Clinical and Operational EvidenceNamed deployments with dated outcome figures and enough method to test them, or published research short of independent validation.
Vendor Published

The main evidence is a multi institutional comparative effectiveness study published as a 2020 Journal of Clinical Oncology meeting abstract: 24 independent radiologists and 20 independent oncologic providers evaluated body CT from 120 consecutive patients with advanced cancer on systemic therapy, using current practice and AI assisted methods.

With AI Metrics, average read time fell from 18.7 to 9.8 minutes, reporting accuracy rose from 73% to 91%, inter observer agreement rose from 46% to 73%, major errors fell 99%, and 96% of radiologists and 100% of oncologists preferred it. An earlier study of eMASS, linked to JCO Clinical Cancer Informatics, found it reduced errors and halved evaluation time without AI algorithms.

DD on AI Safety and PHI StewardshipNothing published on how protected information moves through the system.
Vendor Published

Nothing covers how patient images, measurements and reports are handled. The only privacy document is a generated website policy for AI Metrics LLC covering contact details, usage data, cookies and web beacons on aimetrics.com, with Alabama named as the governing country, and its subject is the website. Installation is promised as secure and cloud based.

Nothing sets out retention of studies and reports, de identification, whether customer images and the tumor segmentations radiologists confirm feed the algorithms, or how a mismeasured lesion or a wrong label is caught and corrected.

Regulatory and Compliance
DD on HIPAA and BAA PostureNo statement of status and no privacy document that reaches the product. Both halves are absent at this grade: a service level privacy document on its own lifts a vendor to the band above even where no status is stated. A website privacy notice, including one that says it does not cover customer data, does not reach the product, so a vendor whose only document is that notice and who states no status grades here.
Vendor Published

No HIPAA or business associate position is taken. AI Metrics handles CT and MR studies, prior reports and patient level tumor measurements for radiology groups and hospitals, and connects to PACS, RIS and EMR, yet the one privacy document is a website notice built from a policy generator, covering personal data visitors submit, usage data and cookies. It names AI Metrics LLC at 1500 First Avenue North in Birmingham and Alabama as the governing country. No service privacy terms, data processing terms or agreement template are offered for the imaging product, which radiologists use on live patient studies.

DD on Security Certifications and Trust CenterControls are asserted with nothing independent behind them, or nothing is published. Read the note before concluding anything: this is the grade most often corrected on a second pass, because assurance material frequently sits on a parent domain or inside an old announcement rather than on the product pages.
Vendor Published

Security comes down to a secure cloud based installation and sign in with Active Directory credentials, with the team working alongside a customer's IT staff and images loading in context on top of the customer's own PACS viewer. Before clearance the software was tested on Linux systems by the development and quality control teams, with a hazard analysis finding all risks acceptable, and no cybersecurity testing is listed. No SOC 2, ISO 27001, HITRUST, penetration test or trust center is named for a product that sits inside the radiology workflow, reads from the PACS and holds patient imaging and reports.

BB on FDA and Regulatory StatusThe pathway is stated and in progress, or a clearance is named without the vintage and scope a buyer needs to match it to the product on offer. A product outside device regulation also sits here when the vendor publishes what it is for and in what setting and the product on offer matches, or names another regime it works under, such as a registration outside the United States. A general clause saying the service is not medical advice does not reach this band.
Regulatory Filing

AI Metrics holds 510(k) K202229, cleared 22 December 2020 under 21 CFR 892.2050, picture archiving and communications system, product code LLZ, Class II, with mint Lesion (K142647) as predicate. The indication covers viewing, annotation, analysis and comparison of CT and MR images over time, semi automatic lesion segmentation and labeling suggestions for user selected regions, and structured reports, as a workflow automation tool that does not directly generate any diagnosis or potential findings; the cleared software is identified only as a release candidate that passed its critical tests. AI Metrics sells algorithms that automate tumor identification and the product as "an extra set of eyes for radiologists", without naming the clearance.

DD on AI Governance and Bias DisclosureNothing published on how model behavior is governed or tested. Multilingual operation with no subgroup performance sits here when the vendor markets recognition quality as a strength, because a caller the system failed to understand leaves no complaint and no record.
Vendor Published

No document explains how the measurement and labeling algorithms are tested before release, monitored in use or checked across patient groups, scanners, tumor types or between CT and MR. The comparative study reports agreement between radiologists rising from 46% to 73% with the tool, a measure of consistency between readers, and before clearance verification ran through the development and quality control teams with a hazard analysis.

No subgroup results, responsible AI policy or customer review material appear. Advisors from radiology and oncology helped design the product, and its chair, Dr. Smith, co chairs an emerging technology commission on AI at the Society of Abdominal Radiology.

CC on AI Liability and RecourseMechanisms exist that let someone challenge an output, such as audit trails, source traceability or review before commit, with nothing standing behind the output and no route for the harmed party.
Vendor Published

The checks sit in the workflow. The radiologist confirms each target slice before the algorithm measures it, assesses non target lesions directly and can annotate manually, and the clearance leaves diagnosis with the medical professional.

Study figures cover the tool in use, reporting accuracy of 91% against 73% for current practice and a 99% fall in major errors over 120 patients, from a 2020 Journal of Clinical Oncology meeting abstract with 24 radiologists and 20 oncologic providers, without an error rate for the algorithms themselves. No guarantee, indemnity or correction route for a wrong measurement or report is offered, and no customer terms are available.

Integration and Deployment
CC on EHR and Interoperability DepthIntegration is claimed through standards or a middleware layer with no system named and nothing to verify.
Vendor Published

Integration is offered without names: seamless integration with existing worklists, images loading in context on top of the normal PACS viewer, Active Directory sign in and interoperability with the PACS, RIS and EMR, while the cleared device communicates, stores and displays DICOM compliant CT and MR data. The Co-Pilot reviews prior and preliminary reads and tracks incidental findings across exams.

No PACS, RIS or EMR vendor, HL7 or FHIR interface, or deployment where the connection runs is named. The report goes to oncologists as graphs, tables, key images and structured text, and nothing shows the route by which it reaches the record.

CC on Deployment Model and Data ResidencyA single hosted option with location implied rather than committed.
Vendor Published

Installation is secure and cloud based, set up by the AI Metrics team alongside the customer's IT staff for fast, simple integration with existing systems, with images loading in context on top of the customer's PACS viewer and users signing in with Active Directory. The cleared software runs on general purpose hardware on a native or virtualized Linux platform, deployed by internet download and installed by trained AI Metrics technicians. No on premises option is offered by name. Nothing says where images, measurements and reports rest, in which region, or how customers' data is kept apart.

Commercial
DD on Commercial TransparencyNothing a buyer can establish before a sales conversation. A published pricing claim contradicted by evidence also grades here.
Vendor Published

No price, pricing basis or licensing model is given, and every page ends with a request to schedule a demo or contact the company. The company frames its value in cost terms: cancer reads are among the lowest margin work on a radiologist's worklist, and the software turns them into a high margin, time saving deliverable by halving read times.

A radiologist at Hampton Roads Radiology Associates speaks for the product, and the company raised a $1.26 million bridge round in October 2022, led by an angel fund and investors including radiologists, to fund research and development.

BB on Setting and Specialty CoverageCoverage is named with validation behind part of it.
Vendor Published

The scope is narrow and named: longitudinal response evaluation of patients with advanced cancer on CT and MR, under user selected criteria such as RECIST 1.1, for radiology and oncology teams, with the report written for oncologists and patients. Validation covers the CT part: the comparative study used body CT from 120 consecutive patients with advanced cancer treated with systemic therapy, read by radiologists and oncologic providers from several institutions. MR reads and other response criteria rest on no study. Dr. Smith's separate CT biomarker for liver fibrosis, which won a Best of AJR award, belongs to his research, not the cleared product.

Alternatives

Alternatives to AI Metrics

Other products that do the same kind of work as AI Metrics, and what each one does.

MosaicOS is a cloud radiology platform from Mosaic Clinical Technologies, the technology subsidiary Radiology Partners launched in July 2025.

iMeasure is Better Medicine's CT lesion measurement service, sold as an API for the viewers, PACS and trial reading platforms radiologists already use, and shown on its site under the BMVision line as BMVision XCS.

New Lantern sells a cloud based radiology platform that replaces a practice's PACS, worklist and reporting software with one browser workspace.

mediaire, a Berlin company founded in 2018, sells the md suite, MRI analysis software that radiology practices and hospital departments install on their own network.

Better Medicine builds AI for reading abdominal CT, starting with BMVision Kidney, which detects kidney lesions as small as 5 mm, draws their boundaries in 3D, measures the longest dimension and three orthogonal axes, and separates likely malignant from benign findings for a radiologist to review.

RadioReport, sold as RadioReport Automatic AI by Neo Q Quality in Imaging GmbH of Berlin, is guided structured reporting software for CT and MRI.

Commercial

Pricing

Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.

Entry Price Pricing Basis BAA Tier Implementation Source
Not published
No pricing basis is published; the company takes demo requests. No business associate position is published. Not published. The AI Metrics team installs the software alongside the customer's IT staff. Vendor Published

No unit of charge, tier or contract term is given. The company frames the value as turning low margin cancer reads into faster, higher margin work, with read times cut from 18.7 to 9.8 minutes in its comparative study.

Contact us

Found a vendor we missed? Have feedback on the index? We’d love to hear from you.