Radiology & Imaging AI
A

a2z-Drafter

a2z-Drafter is a2z Radiology AI's European software for prioritizing CT studies and preparing material for radiology reports. It analyzes adult scans of the head, chest, abdomen and pelvis, with or without contrast. The software recognizes 182 radiological findings and adds attributes to selected observations. The set includes acute findings such as subarachnoid hemorrhage and pneumothorax, findings that can require prompt workup such as obstructing ureteral stones, and observations for routine follow up.

The software assigns a priority category to each finding. A provider's existing worklist uses those categories to help organize the next reads. A structured list of findings and attributes is available to the reporting system to prepare draft report content. The radiologist reviews the full study independently and retains responsibility for the interpretation and clinical decision. The product connects to the imaging archive, radiology information system and worklist in the reading environment.

The European offer is a Class IIb medical device under the EU Medical Device Regulation, certified in November 2026 with Scarlet as notified body, and Spain is the registered country of first placement. In the United States the product is not FDA cleared and not on sale. a2z Radiology AI, based in Boston, was cofounded by Pranav Rajpurkar of Harvard Medical School and Samir Rajpurkar and is backed by Khosla Ventures and SeaX Ventures.

AI Health Index verifiedNovember 25, 2026
Compare a2z-Drafter with other vendors
Founded
—
Headquarters
Boston, Massachusetts, United States
Categories
radiology-and-imaging-ai
Indexed Products
a2z-Drafter
Buyer Segments
EU Radiology Providers, Hospital Radiology Departments, Imaging Networks
Assessment

Capability Axes

An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read

AI Capability
AA on AI CentralityThe artificial intelligence is the product. Remove the model and there is nothing left to sell.
Vendor Published

The software analyzes CT images to recognize and characterize findings that a radiologist needs to consider during a read. It works across scans of the head, chest, abdomen and pelvis in adults, including noncontrast and contrast studies. The detector produces findings in 182 categories and adds attributes for selected observations. Those outputs give the worklist information for prioritization and the reporting system structured material for a draft. The same findings can support immediate review and routine follow up. The learned image analysis is what supplies both the priorities and the substance of the draft.

BB on Autonomy and Oversight ModelThe oversight structure is described and one part is missing, commonly the threshold at which the system stops or what happens after it is wrong.
Vendor Published

Each detected observation carries a priority category. The local worklist can use it to schedule the reading, and the reporting system receives findings and selected attributes for draft content. The radiologist independently reads the full study and reviews the generated material before it becomes part of a report. Acute and nonacute findings can appear together in one exam, with the same physician responsible for interpretation. That decision stays with the physician even when priority categories change the reading order. The product does not define the numerical threshold or worklist override control for each priority.

CC on Model and Technology TransparencyThe architecture is described in general terms with nothing identified. Proprietary is asserted rather than explained.
Vendor Published

The software takes CT scans as input and returns structured findings, selected attributes and a priority category for each finding. The model supports scans acquired with or without contrast and covers four regional parts of the body. The reporting system turns the structured observations into a starting point for the radiologist's draft. The worklist can use the categories independently of the report generation step. The imaging analysis and the draft handoff are specified as separate actions, with the training population, model release and update history for the EU detector still undefined.

BB on Model Supply Chain DisclosureSubstantial partial disclosure, or a chain that is structurally short: an in house build, a cleared model that cannot be quietly swapped, or a deployment where the transfer does not occur at all. Naming the model provider exits the band below into this one; the axis rises from here on the completeness of the party list and on the terms that govern data once it arrives.
Vendor Published

a2z Radiology AI supplies the imaging model and the software that translates detections into findings and priority codes. The device works in conjunction with the provider's archive, worklist and reporting system. The radiology provider uses that structured output to make the next task visible and prepare draft content for a physician. Casus Europe acts as the authorized regulatory representative in the European Union. The provider's model processing and any onward transfers have no named subcontractor chain specific to this deployment.

CC on Clinical and Operational EvidenceNamed customers, or vendor reported percentages with no method, denominator or reference standard. Scale of use is recorded here and is not treated as evidence of benefit.
Vendor Published

The certified device covers 182 findings across head, chest, abdomen and pelvis CT, each tested against acceptance criteria set before testing. The findings span emergency and routine radiology, including pneumothorax, bowel obstruction and aneurysm. The marketed device has no per finding sensitivity, specificity or sample size on record.

Mass General Brigham studies announced in November 2026 tested separate research models in inpatient, emergency, dose comparison and pediatric work, and a2z labels those models research use only, not cleared for clinical or commercial use.

DD on AI Safety and PHI StewardshipNothing published on how protected information moves through the system.
Vendor Published

The detector evaluates images in a radiology workflow supervised by licensed readers. It gives the worklist priorities and returns structured observations to the reporting system, where a clinician reads the full study before finalizing the report. a2z restricts model training on personal information collected during website use.

The CT inputs handled by the EU device are a distinct clinical data stream, and their retention within the service, removal of patient identifiers and permitted reuse for training have no device specific commitments.

Regulatory and Compliance
DD on HIPAA and BAA PostureNo statement of status and no privacy document that reaches the product. Both halves are absent at this grade: a service level privacy document on its own lifts a vendor to the band above even where no status is stated. A website privacy notice, including one that says it does not cover customer data, does not reach the product, so a vendor whose only document is that notice and who states no status grades here.
Vendor Published

The software takes CT images from a radiology provider's workflow and returns findings and attributes for use in worklists and drafts. The clinical decision remains with the interpreting physician. a2z Radiology AI's organizational privacy commitments address matters such as account inquiries, demo booking, analytics and data transfers. The EU device has a named representative in the Netherlands for its regulated role. The product's treatment of patient scans has no defined agreement for data processing on behalf of a hospital under the applicable privacy regime.

DD on Security Certifications and Trust CenterControls are asserted with nothing independent behind them, or nothing is published. Read the note before concluding anything: this is the grade most often corrected on a second pass, because assurance material frequently sits on a parent domain or inside an old announcement rather than on the product pages.
Vendor Published

a2z Radiology AI maintains a vulnerability disclosure process for its medical device software. Issues are assigned a severity based on exploitability and possible patient impact, with different patch deadlines and instructions for API and container deployments. The process describes notification to affected organizations and regulators when applicable. The imaging product remains under clinician supervision and feeds an existing PACS and reporting workflow.

Its European certification establishes medical device conformity. An independent security test or organizational security assessment with a scope specific to the Drafter service does not form part of the service's security commitments.

BB on FDA and Regulatory StatusThe pathway is stated and in progress, or a clearance is named without the vintage and scope a buyer needs to match it to the product on offer. A product outside device regulation also sits here when the vendor publishes what it is for and in what setting and the product on offer matches, or names another regime it works under, such as a registration outside the United States. A general clause saying the service is not medical advice does not reach this band.
Regulatory Filing

a2z-Drafter is registered in the European Union as a Class IIb device under Regulation 2017/745. Its device identifier is 00860015344502 and Spain is the recorded member state of first placement on the EU market. Scarlet NB B.V., notified body 3022, is named in its certification for adult head, chest, abdomen and pelvis CT, including triage and preparation of report content. Casus Europe B.V. is the authorized representative. The radiologist independently reviews the whole study. Commercial availability is limited to the European offer. The US clearances held by a2z cover separate acute triage devices.

CC on AI Governance and Bias DisclosureResponsible artificial intelligence is committed to in policy language with no evaluation behind it. Most of the index sits here.
Vendor Published

Practicing radiologists guide model development at a2z Radiology AI, and the Drafter workflow assigns the final interpretation to the physician reviewing the whole exam. The product was evaluated by finding under criteria defined before testing, covering head, chest, abdomen and pelvis. Some detected findings include additional attributes for use in drafts. The categories for hemorrhage, pneumothorax and other observations are functions of the device. No results compare the marketed model's performance by age, sex or other groups of the adults it serves.

CC on AI Liability and RecourseMechanisms exist that let someone challenge an output, such as audit trails, source traceability or review before commit, with nothing standing behind the output and no route for the harmed party.
Vendor Published

A radiologist receives the structured findings, selected attributes and associated priority categories. The physician independently reads all images and reviews draft report content in the provider's system. The review gives a physician an opportunity to correct a draft and reconsider the priority based on the source study. a2z Radiology AI uses severity to prioritize reports of software vulnerabilities and schedule fixes. It sets different patch deadlines by risk and system type. The European offer has no corresponding correction or compensation obligation for an erroneous clinical finding.

Integration and Deployment
CC on EHR and Interoperability DepthIntegration is claimed through standards or a middleware layer with no system named and nothing to verify.
Vendor Published

The software is designed to work with a provider's PACS, radiology information system, existing worklist and reporting application. Its structured output gives the worklist a priority per finding, and the reporting application can use attributes and findings to create draft content. The resulting interpretation belongs in the reading team's reporting process. A scan can carry routine findings alongside higher urgency observations, so a priority applies to a specific finding. The devices form a defined intake and output workflow, but the Drafter offer does not name a production PACS or provide a report write interface by vendor.

DD on Deployment Model and Data ResidencyNothing published about where the system runs or where the data rests.
Vendor Published

Drafter processes adult CT studies in a radiology department's existing imaging and reading workflow. It makes the findings available to the worklist and reporting software. The company's device security process assigns different patch responsibilities to hosted API and container deployments. The EU product has a distinct registration and commercial agreement. Spain is the market entry location in the registration. The current EU offer does not establish where the software runs or where clinical images are stored.

Commercial
DD on Commercial TransparencyNothing a buyer can establish before a sales conversation. A published pricing claim contradicted by evidence also grades here.
Vendor Published

a2z Radiology AI offers the device directly to radiology providers in the European Union through an enterprise conversation. The software is sold for adult CT, including head and chest imaging as well as abdomen and pelvis studies. Its worklist and reporting handoffs use the customer's imaging and radiology systems, so the deployment involves the existing reading environment. Spain is the country recorded for its EU market entry. The commercial agreement sets the license and implementation charges, and a department has no way to size the price from a scan rate, seat count or named tier.

CC on Setting and Specialty CoverageCoverage is claimed broadly without specifics, or stated clearly with nothing validating it yet.
Vendor Published

The device serves hospital and outpatient radiology departments reading CT in adults aged 18 and older. It analyzes eligible head, chest, abdomen and pelvis studies both with contrast and without it. Acute bleeding, shifted brain structures and pneumothorax are examples of findings that could move a study up a worklist. The same product can return routine observations for follow up in the report. The certified product reached the EU market in November 2026, and no emergency, inpatient or outpatient department is named as a user.

Alternatives

Alternatives to a2z-Drafter

Other products that do the same kind of work as a2z-Drafter, and what each one does.

a2z Radiology AI sells a suite of three CT triage devices for US radiology departments and health systems. The software analyzes eligible abdomen and pelvis CT studies in adults aged 22 and older.

Harrison.ai, headquartered in Sydney, sells radiology AI that until 2025 was sold under the Annalise.ai name. Harrison.ai combined with Annalise.ai in February 2025 and renamed the Annalise products in October 2025, and the annalise.ai domain now forwards to harrison.ai.

Aidoc sells clinical AI for imaging triage and follow up to health systems, delivered through aiOS, an enterprise platform that runs Aidoc's own FDA cleared algorithms alongside vetted partner algorithms and carries care coordination and patient management.

Lithuanian radiology AI developer based in Vilnius, part of Sectra, the enterprise imaging company, since 2026.

Romanian imaging AI company based in Timisoara whose Rayscape CXR analyzes chest X-rays, detecting and localizing 148 findings across 17 clinical classes, including tuberculosis, with bone suppressed views, an automatic cardiothoracic ratio and a normal or abnormal flag for worklist…

New Lantern sells a cloud based radiology platform that replaces a practice's PACS, worklist and reporting software with one browser workspace.

Commercial

Pricing

Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.

Entry Price Pricing Basis BAA Tier Implementation Source
Enterprise quote
a2z Radiology AI sells the adult CT device to EU radiology providers through an enterprise agreement. Patient image processing terms are handled through the provider's contract. Integration with the existing PACS, worklist and reporting system is part of the deployment scope. Vendor Published

The license covers a2z-Drafter for adult CT triage, detection and report drafting in the European offer. The proposal determines whether the charge is based on a site, studies or another measure.

Contact us

Found a vendor we missed? Have feedback on the index? We’d love to hear from you.