Vista AI
Vista AI, a Redwood City company formerly known as HeartVista, sells Vista AI Scan, software that automates cardiac MRI so a hospital's or imaging center's existing technologists can run an exam that usually takes specialist staff. It runs on a dedicated Ubuntu workstation beside the console of compatible GE Healthcare and Siemens Healthineers scanners, and its models find landmarks and plan imaging planes, select coils, segment cardiac anatomy, tune sequence parameters, flag motion and other artifacts on supported sequences in real time, and return preliminary measurements before the patient leaves. Protocols for cardiomyopathy, stress, ventricular arrhythmia, valvular and pericardial disease can mix more than 30 Vista sequences with the scanner's own, and the technologist reviews each proposed plane and can change it or rescan.
Images stay on the encrypted workstation and return to the scanner over DICOM, with a separate connection for remote support and centralized oversight across sites, and the VistaHub cloud handles analytics and support. FDA cleared version 3.4.0 under K260092 in October 2026, adding spine localizers, while the marketed offer remains cardiac. RTHawk Research is the research product inside the platform: an investigational workspace on the same engine where academic MRI groups at Stanford, UCSF, USC, the University of Wisconsin and Sunnybrook design pulse sequences in SpinBench, run real time reconstruction and test new applications on scanner simulators.
At Brigham and Women's Hospital, a study of 6,545 cardiac MRI exams from 2020 to 2024 found Vista assisted scans took 37.9 minutes on average against 49.2 for operator directed scans, with fewer exams needing a repeat, and Radiology Regional runs it in outpatient imaging. Vista cites 26% faster scans and cardiac MRI access in one day instead of a 28 day backlog. Sites buy through a demonstration, and most go live within days.
Capability Axes
An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read
The models do the work cardiac MRI usually needs a specialist for. Separate networks find landmarks and propose imaging planes, segment cardiac anatomy and detect motion and artifacts, and the workstation tunes parameters and adapts acquisition from that feedback, which is what lets general technologists run the exam.
Underneath sits Vista's RTHawk acquisition platform, which controls the scanner, runs more than 30 cleared pulse sequences, reconstructs and displays images and combines Vista and scanner sequences into protocols. Without the models it becomes a manual sequence controller that needs a trained cardiac technologist at the console, which is the dependence the product is sold to remove, so the core job rests on the models.
The technologist controls the scan. The workstation proposes imaging planes and segmentation measurements that the technologist can accept, modify or reject, and it alerts on problems such as motion or poor myocardial nulling so a series can be repeated; the device runs beside the scanner console, and a physician reads the finished images.
The operating thresholds behind the quality alerts are not given, artifact detection covers only certain sequences, and no fallback is described for a patient the system cannot plan or assess, so the structure is clear while the point at which it hands back to a person is not.
The models are identified by function, data and version. Vista AI Scan uses separate neural networks to propose imaging planes, segment cardiac anatomy and recognize artifacts, running on the local workstation, and the 3.4.0 clearance describes each model with its verification set, training, tuning and test data separated by patient, and cardiac cine series among the test examples.
The change control plan sets out how localization and quality models may be extended, the acceptance criteria an update must meet and that customers are told before an affected version is installed, so a site can match the version it runs to its intended use and validation.
The scan models are Vista's own, cleared and running on the facility's workstation on images that move only between it and the scanner, so no outside model provider receives patient scans, and the change control plan limits how those models can change.
The Vanta trust center lists subprocessors for the rest: DigitalOcean for cloud services, Canonical for the operating system, and others for version control and corporate services. What support staff and VistaHub's cloud receive from a site, and how long those parties hold it, is not given.
A peer reviewed study at a named customer carries the evidence. Brigham and Women's Hospital compared 6,545 cardiac MRI studies in 6,080 patients from January 2020 to April 2024 (JACC: Advances, 2026): mean acquisition took 37.9 minutes with Vista against 49.2 minutes operator directed, and failures needing a repeat within 90 days fell to 0.6% from 1.4%, with the comparison spanning five indications and adjusted for patient differences and technologist experience; survival over a median 29 months did not differ.
The study was single center and nonrandomized and used software version 3.2. Vista's own site cites 26% faster scans, 50% more scan slots and access in one day rather than 28, without saying which sites those figures come from.
The models run on the site's own workstation, which receives MRI data over a secure local channel and keeps it on an encrypted drive, so scans are not sent out for inference. Model verification uses data separated from training by patient identifier, and the artifact detector warns the technologist so an affected series can be repeated.
No commitment covers what support staff or VistaHub may keep from a site's data, for how long, or whether it may be used to train future models under the change control plan, and no process is described for tracking a safety event involving a model's plan or quality call.
Protected data stays inside the facility in normal use. The scanner sends raw MRI data with patient details to the dedicated workstation over an encrypted link, the workstation keeps it on an encrypted drive, and images return to the scanner over DICOM; Vista describes the scanning and analytics platform as HIPAA aligned.
Remote support connects through a separate hospital network link and VistaHub collects analytics, both of which can reach protected information, and no business associate status, agreement or scope for those activities is published.
SOC 2 Type 2 is named with its auditor. 360 Advanced examined Vista AI Scan and VistaHub against the Security and Confidentiality criteria, and the Vanta hosted trust center lists penetration testing, encryption, configuration management, access controls and data retention procedures; device quality runs under ISO 13485. At the site, the workstation's drive and the scanner link are encrypted.
The report is released to customers and prospects under a mutual nondisclosure agreement rather than opened directly, so its reporting period and findings are visible only after signing.
FDA cleared Vista AI Scan 3.4.0 under K260092 on October 7, 2026 as an accessory to specified GE Healthcare and Siemens Healthineers whole body MRI systems, controlling acquisition, reconstruction and display beside the scanner console at supported field strengths, with a change control plan for updates to localization and artifact detection. The earlier K251029 covers Vista OS, Vista AI Scan and RTHawk.
The 3.4.0 clearance includes spine localization and new cardiac quality tools, while the commercial offer remains cardiac MRI. Images are interpreted by trained physicians for diagnosis, and the RTHawk Research workflow carries separate investigational conditions.
Performance is reported across the imaging sources the product serves. The 3.4.0 motion artifact model, tested on 248 cine slices from 175 studies, reached 81.9% accuracy overall, 86.2% on GE images, 85.2% on Siemens images and 75.3% on images from Vista's own sequences, with clinical readers independent of development and verification images separated from training by patient. The Brigham and Women's study compared acquisition across five indications and technologist experience levels.
FDA cleared a change control plan governing updates to localization and artifact detection. Results by patient age, sex, body size or heart rhythm are not reported.
Mistakes surface at the scanner. The workstation shows its proposed planes for the technologist to accept or change, alerts on detected quality problems so a series can be repeated before the patient leaves, and keeps the source images, which go to the scanner for the normal reading workflow.
Vista takes on no obligation for an error that gets through. No remedy, correction commitment or route for a site or patient attaches to a misplanned exam or a missed artifact that leads to a repeat scan.
Vista connects to scanners rather than record systems. The workstation controls compatible GE Healthcare and Siemens Healthineers MRI systems beside the console, connecting through the Siemens Access router on Siemens installations, exchanges acquisition data over an encrypted link, and returns finished DICOM images to the scanner workstation for the site's usual PACS and reading workflow. Scanner native and Vista sequences combine in one protocol where supported.
Those are named, production integrations with imaging equipment. The workstation has no connection to an electronic health record, PACS, radiology information system or hospital information system of its own.
The scan runs on premises. Vista AI Scan installs on a physical Ubuntu workstation the customer sources and connects to the scanner, raw images and patient details stay on that workstation and the scanner, encrypted in transit and at rest, and a separate hospital network connection carries remote technical support. Sites can deploy singly or across a network with centralized oversight.
VistaHub, the cloud environment for analytics and operations, sits in the SOC 2 scope, with no storage location, telemetry list or separation of support access between customers committed for it.
Vista AI Scan is sold through a demonstration, scoped to the site's scanner models. The customer sources the dedicated workstation, Vista checks compatibility, loads the site's protocols and connects the scanner, and the software can run at one location or across a network with centralized oversight; most sites go live within days.
No software price, billing unit, per scanner or per exam rate, or separate implementation or support fee is published. What installation involves is clear, while how cost scales with scanners, sites or exam volume comes only with a quote.
The marketed setting is cardiac MRI in hospital programs and outpatient centers with compatible GE or Siemens scanners, with protocols for cardiomyopathy, stress imaging, ventricular arrhythmia, valvular disease and pericardial disease, run by technologists who need not be cardiac specialists.
The Brigham and Women's study measured acquisition across those five indications and across technologist experience levels, and Radiology Regional runs the software in an outpatient setting. The 3.4.0 clearance adds spine localizers, but spine and other anatomies are not part of the current offer, so validated coverage matches what is sold.
Alternatives to Vista AI
Other products that do the same kind of work as Vista AI, and what each one does.
MRIguidance, a Utrecht company founded in 2016 with a US office in New York, sells BoneMRI, deep learning software that turns a dedicated 3D gradient echo MRI sequence into CT like images of bone, so spine and pelvic bone can be assessed from an MRI without the radiation of a CT scan.
Copenhagen company, founded in 2018, whose Apollo software reads brain MRI while the scan is still running.
inHEART turns cardiac CT and MRI scans into three dimensional digital twins that electrophysiology teams use to plan and guide catheter ablation, mainly for ventricular tachycardia.
Seoul based MRI AI company with US operations. SwiftMR is a deep learning enhancement tool that reduces noise and sharpens MRI images after acquisition, so sites can scan faster or get better images from the same scan.
Foqus Technologies, a Kitchener, Ontario company cofounded by Dr. Sadegh Raeisi, sells DeepFoqus-Accelerate, AI reconstruction software that lets an MRI department scan the brain up to four times faster.
Deep learning software that enhances and accelerates image acquisition on existing scanners rather than detecting disease.
Pricing
Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.
| Entry Price | Pricing Basis | BAA Tier | Implementation | Source |
|---|---|---|---|---|
|
Commercial quote after demo
|
Hospitals and imaging centers license Vista AI Scan for compatible scanner installations. Purchase scope is configured through sales for individual locations or groups. | The scan runs onsite and handles protected MRI data locally. Business associate coverage for scanning, support or analytics is not published. | A dedicated workstation is sourced by the customer. Scanner compatibility, local configuration and protocol setup are part of implementation. Software and support fees are quoted. | Vendor Published |
The demonstration presents the commercial cardiac workflow, and purchasing depends on the site's scanner models, workstation and protocols. No software rate or fee schedule is published, and most sites go live within days.