Behavioral Health AI
S

Sonde Health

Sonde Health licenses vocal biomarker software to employers, healthcare organizations and companies that build connected health products. Its API and software development kits take voice from a customer application or device and return health related scores. Mental Fitness tracks changes in vocal characteristics and can add a transcript when a partner offers voice journaling. Cognitive Fitness assesses changes in cognitive effort. The respiratory check uses two brief held vowel samples to estimate respiratory symptom risk. The active check asks for another sample when the audio fails its quality rules.

The enterprise dashboard aggregates trends across a workforce. Employers use the results within wellness programs, and partners can embed scores in an application or connect them to their own backend. Cognitive Fitness offers a mode that processes the voice on the device without storing or transmitting the recording. Cloud and edge routes are also available for licensed integrations.

The Boston company announced a workforce wellness partnership with Saaya Health in 2025. Its research includes a four week study at Cognitive Behavior Institute that compared the earlier Mental Fitness score with the M3 Checklist and a separate respiratory study that assessed a previous model against PCR confirmed COVID 19 status. Sonde provides a development key for testing and requires a partnership agreement to issue the production key.

AI Health Index verifiedNovember 25, 2026
Compare Sonde Health with other vendors
Founded
—
Headquarters
Boston, MA
Categories
behavioral-health, remote-monitoring
Indexed Products
Sonde Platform Service API, Mental Fitness, Cognitive Fitness, Respiratory Symptoms Risk, Enterprise Performance
Buyer Segments
Employers and occupational health programs, Digital health companies, Health and wellness organizations, Healthcare providers, Device manufacturers
Assessment

Capability Axes

An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read

AI Capability
BB on AI CentralityThe model is the engine of a core module. The platform carries other value, but this capability does not exist without it.
Vendor Published

The service extracts acoustic and prosodic features to give a partner application mental, cognitive and respiratory health scores. The respiratory module estimates symptom risk from a learned scoring model applied to the recording. An earlier reported version used a logistic regression fitted to asthma and healthy control recordings. The clinical study of Mental Fitness used a fixed average of selected features, and that arithmetic can run without a learned scoring model.

The licensed enterprise suite loses automated respiratory risk interpretation when the learned component is removed. The partner application can still collect recordings, administer questions and display the results of remaining measures.

BB on Autonomy and Oversight ModelThe oversight structure is described and one part is missing, commonly the threshold at which the system stops or what happens after it is wrong.
Vendor Published

The respiratory check requires two valid recordings, and a failed elicitation check results in an error or a request to record again. The API returns a relative risk score and can ask additional questions set by the partner. The developer workflow allows an application to display results to the user or deliver them to the organization's backend. The enterprise dashboard summarizes scores over time. The partner therefore controls how scores are presented and whether staff act on them. The organizational workflow has no fixed threshold that routes a person for clinical review across all deployed scoring modules.

BB on Model and Technology TransparencyThe approach or the suppliers are named without the version and update discipline behind them. Naming a supplier is the entry to this band both here and on Model Supply Chain Disclosure, which ask different questions of the same disclosure: who receives the data, and what produces the output.
Vendor Published

The respiratory check estimates similarity to vocal features seen in people with respiratory conditions. Its research predecessor used a fitted logistic regression on acoustic measures from people with asthma and healthy volunteers. Developer releases identify changes to model versions, the score interface and checks that return an error on an unusable sample.

The Mental Fitness research study averaged eight features, while the developer interface also provides an aggregate from its set of acoustic outputs. Where the API returns a respiratory risk band, it also provides a number. The currently licensed model releases do not have complete training provenance across all measures.

BB on Model Supply Chain DisclosureSubstantial partial disclosure, or a chain that is structurally short: an in house build, a cleared model that cannot be quietly swapped, or a deployment where the transfer does not occur at all. Naming the model provider exits the band below into this one; the axis rises from here on the completeness of the party list and on the terms that govern data once it arrives.
Vendor Published

Sonde produces its own respiratory biomarker and offers a software development kit that computes the score on the partner device. The Cognitive Fitness route keeps audio on that device. Hosted processing receives samples in a separate workflow, and Amazon Web Services hosts the named Sonde One application route. Voice journaling can also return a transcript. Partner organizations choose which platform services to combine. No complete list of parties covers the hosted enterprise workflow, including any transcription service and its retention and training terms.

CC on Clinical and Operational EvidenceNamed customers, or vendor reported percentages with no method, denominator or reference standard. Scale of use is recorded here and is not treated as evidence of benefit.
Peer Reviewed Publication

The 2024 Mental Fitness study followed 104 participants at Cognitive Behavior Institute over four weeks and compared an eight feature score with M3 Checklist results. The 2023 respiratory study enrolled 497 people at four sites in the United States and India and assessed an earlier model against PCR status, finding 73.2% sensitivity and 62.9% specificity when comparing people who tested positive with healthy volunteers.

The current respiratory check has changed its model version and input handling since that study period. The 2025 workforce figures come from an unnamed industrial deployment, and no named production customer reports a measured benefit.

CC on AI Safety and PHI StewardshipGeneral assurances of privacy and security that do not answer the questions artificial intelligence raises: what is retained, what reaches a model, and what happens to it there.
Vendor Published

Cognitive Fitness offers local processing with neither storage nor transfer of the underlying voice recording. The cloud respiratory interface accepts audio and returns scores along with quality information. The Sonde One app transmits encrypted samples to its cloud service and limits the research team's work to de identified records. The consumer app terms grant broad rights to use submitted samples, subject to privacy limits. No retention period, training restriction or removal right is committed for an API customer's recordings outside the partner contract, and no incident procedure covers an erroneous score.

Regulatory and Compliance
CC on HIPAA and BAA PostureA status is stated but not supported: compliance is claimed, or business associate status stated, without the underlying document, including where the only privacy notice published covers the website rather than the service that handles patients. The mirror case grades here as well: a substantive privacy document that reaches the service, with no statement of business associate status anywhere and no scope position taken. One of the two elements the band above asks for is present, which is a grade below it and not a grade at the floor.
Vendor Published

The enterprise platform processes vocal measures and may collect limited demographic or symptom information for the partner's configured use. Sonde says it adheres to GDPR and HIPAA and offers device side processing for some routes. Cognitive Fitness can verify the enrolled speaker locally and keep the recording on the device. Partner software receives a live key and updated commercial terms before launch, and the app privacy terms cover Sonde's own applications. No business associate status is stated for the licensed API and SDK.

BB on Security Certifications and Trust CenterA recognized certification is named in the vendor own material without the artifact, or with a scope or renewal question the buyer has to raise. A recognized certification here is an audit of how the vendor operates security, such as SOC 2, HITRUST or ISO/IEC 27001. A certification has a scope and a clock, and both are part of this grade. A certification the vendor attaches to its data center, hosting facility or cloud provider, rather than presenting as its own, is the host's and does not count here.
Vendor Published

The company holds SOC Type 1 and Type 2 certification, with the report family, SOC 1 or SOC 2, left unnamed, and its NIST Cybersecurity Framework 2.0 certification is in progress. Sonde One voice recordings travel encrypted to Amazon Web Services, and embedded Cognitive Fitness verifies the enrolled speaker and processes the voice locally. The health check can also run on an edge SDK that returns a numeric output to the host application. No report or certificate is posted to show which SOC examination applies or whether the enterprise API and device processing fall inside it.

CC on FDA and Regulatory StatusNo device claim is made and the product is scoped accordingly. Most administrative and operational products sit here and are not penalized for it, because this axis grades the appropriateness of the positioning rather than possession of a clearance. A stated limit on use, such as research use only or a clause that the product gives no medical advice, beside marketing that sells the product for clinical decisions also sits here, with both quoted, because the buyer has to ask which one governs.
Regulatory Filing

Respiratory Symptoms Risk reports the likelihood of symptoms such as coughing, shortness of breath and chest tightness from a person's voice. Sonde markets the respiratory API and SDK as one that "detects and monitors for symptoms of COVID-19, asthma, COPD, and several other pulmonary conditions", for remote monitoring of chronic respiratory illness and for patient stratification in medical workflows.

Its developer terms for the active score prohibit use for medical evaluation or treatment, so the marketing and the use limit point in different directions. Mental and Cognitive Fitness track changes in wellness and cognitive effort. None of the scores carries an FDA filing or a claim to one.

BB on AI Governance and Bias DisclosureA governance framework with named process behind it, such as certification to an artificial intelligence management standard, or material written for a customer own review committee to evaluate the product with. A framework covering the vendor whole portfolio counts when its scope reaches this product; what it cannot supply is the product specific evaluation the band above asks for. Published results within the one group where the performance of this product is most at risk also sit here: evaluation on the question this axis asks, short of the comparison across groups the band above requires. A medical device clearance or certification, and the quality system behind it, does not reach this band on its own; it is graded under regulatory status. A regulator reviewed plan governing how the model may change does reach it.
Vendor Published

The respiratory workflow checks sample quality before returning a score. Before a partner goes live, Sonde supports testing recordings, scores and the messages used to request another sample. The 2023 respiratory study reported different sensitivity and specificity at United States and India sites, and also examined performance by age, sex, language and symptom status. The later product documentation records model changes and a revised method that combines two samples. That subgroup evidence belongs to the earlier learned model, and no subgroup results exist for the respiratory release licensed today.

CC on AI Liability and RecourseMechanisms exist that let someone challenge an output, such as audit trails, source traceability or review before commit, with nothing standing behind the output and no route for the harmed party.
Vendor Published

Sonde's respiratory score is based on voice characteristics and the application can request a new sample after an audio quality error. Partner implementations decide whether to display a score and description to the individual or transfer it to the organization's system. Enterprise onboarding includes validation of the audio path and messaging. The score help describes influences that can make the result differ from a person's actual condition. The service gives the partner an error and repeat flow. The enterprise license has no contractual remedy for an incorrect biomarker assessment.

Integration and Deployment
CC on EHR and Interoperability DepthIntegration is claimed through standards or a middleware layer with no system named and nothing to verify.
Vendor Published

A partner sends audio and supporting inputs to the health check interface or embeds a library in its product. The service returns Mental Fitness or Respiratory Symptoms Risk scores for display and can send results to a partner backend. Optional voice journaling returns a transcript. Some device routes compute the score locally and support later upload of the score itself. Every connection runs through the partner's own application, and no named connection writes a score into a production electronic health record.

BB on Deployment Model and Data ResidencyOptions and residency are stated with isolation or the processing path left open.
Vendor Published

Sonde offers hosted, edge and embedded routes. The cloud route scores submitted audio and can return the results to a partner system. The published mobile SDK can compute scores on a device, and the Cognitive Fitness mode keeps audio local without storing or transmitting it. Sonde One uses Amazon Web Services for encrypted uploads. The organization can choose to use an individual score for display or move it into its own backend. No cloud region or isolation between shared deployments is committed for the hosted route.

Commercial
BB on Commercial TransparencyA price or a pricing basis is published without full tiers, so a buyer can size the cost before making contact.
Vendor Published

The staging service provides a test key and up to 250 free vocal biomarker calls. Sonde puts the respiratory check at a few cents per health check when used daily, and production use requires a partnership agreement and a separate live key. The standard trial route supports respiratory symptom scoring, and some mental fitness integrations require discussion with the support team. Enterprise Performance includes an organizational dashboard, while the SDK can go inside a customer application. The partnership agreement sets the exact per call or device rate and the usage limits.

CC on Setting and Specialty CoverageCoverage is claimed broadly without specifics, or stated clearly with nothing validating it yet.
Vendor Published

The company sells the platform for workplace wellness, health and wellness applications and provider programs. Its dashboard shows mental, cognitive and respiratory trends across a workforce, and Enterprise Performance targets fatigue and burnout among industrial workers. The respiratory check is offered for tracking symptoms over time in people with chronic airway conditions.

Clinical research has covered outpatient mental health care and respiratory cases in hospitals in the United States and India. Those studies used earlier study applications and scoring releases, and no employer or device deployment reports measured performance.

Alternatives

Alternatives to Sonde Health

Other products that do the same kind of work as Sonde Health, and what each one does.

Callyope is a French company building an audio and language foundation model trained specifically on psychiatric data rather than adapted from a general purpose speech model.

Canary Speech sells the model rather than the application.

Upvio sells Vitals AI to telehealth providers, pharmacies, insurers and workplace wellness programs. The software uses a phone, tablet or computer camera to estimate physiological signals from a face scan that takes about 30 seconds.

Voice AI care management for health plans and at risk providers. The company originated in vocal biomarker research for detecting depression and anxiety from acoustic features, backed by more than ten peer reviewed publications, and that technology is still the engine.

Aiberry sells anonymous mental health screening to organizations, positioned as a digital front door to care rather than as care.

Digital cognitive assessment and care planning platform.

Commercial

Pricing

Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.

Entry Price Pricing Basis BAA Tier Implementation Source
A few cents per health check
Sonde prices the respiratory check at a few cents per health check when used daily, and the staging key provides up to 250 vocal biomarker calls for evaluation. Commercial deployment requires a partnership agreement and a live key. The partner chooses the measures and cloud, edge or embedded route. The platform is offered with HIPAA controls. The enterprise agreement governs business associate and handling terms for partner data. Sonde works with the partner to validate audio and scoring before launch. Implementation and production fees are determined in the partnership agreement. Vendor Published

The free allowance applies to development testing. The partnership agreement sets the exact per call or device rate and the usage limits for the live key.

Contact us

Found a vendor we missed? Have feedback on the index? We’d love to hear from you.