Hospital & Unit Operations
D

Davix

Davix sells a modular hospital and clinic operating system under the Davix ERPX name. A hospital network can schedule visits, register admissions and maintain a single record across authorized locations. Staff can work from the same chart when they review prescriptions, lab results, imaging orders or notes from previous visits. The platform also supports electronic billing through Peru's SUNAT, calculates patient copays and keeps stock counts and expiration dates by facility.

The radiology module connects to imaging equipment and sends appointment data to the modality worklist. It brings DICOM studies into a browser viewer where radiologists compare current and prior exams, take measurements and sign reports remotely. Once results are authorized for release, patients and referring physicians can open them in their portals. Patients can download images or send a secure link to a physician.

Davix adds voice dictation and assistance for clinical documentation. The documentation workflow suggests ICD 10 codes for clinician confirmation, and a patient assistant explains individual lab results in plain language. The Enterprise imaging tier combines a more advanced viewer, physician assistance and access across sites. The lab and imaging modules share their results with the hospital record so a doctor opening a chart can see the orders, reports and treatment history together.

Davix Health S.A.C. is a Peruvian company backed by Universidad Peruana Cayetano Heredia and the Bioincuba incubator. Its customers include Clínica ConfíaSalud, Hospital Regional Julio César Demarini and Clínica Internacional San Rafael, and it lists AWS, Corti and Anthropic as technology partners.

AI Health Index verifiedNovember 25, 2026
Compare Davix with other vendors
Founded
—
Headquarters
Peru
Website
davix.ai/
Categories
hospital-operations, radiology-and-imaging-ai
Indexed Products
Davix ERPX, Davix PACS/RIS, Davix HIS, Davix LIS, Asistente Davix
Buyer Segments
Hospitals and clinic networks, Imaging centers, Diagnostic laboratories
Assessment

Capability Axes

An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read

AI Capability
CC on AI CentralityArtificial intelligence is a feature layer on a product whose value stands without it. A learned component is a model whose parameters are estimated from data: machine learning, or a statistical model fitted to population data, including one then updated on the patient measurements. A fixed formula, a rule set, or a feedback controller that adjusts a dosing factor from the patient own readings is not one, however patient specific its output and whatever the vendor calls the adjustment.
Vendor Published

The documentation tools help clinicians compose notes and suggest ICD 10 codes. Enterprise imaging adds voice dictation, and a patient assistant translates individual results into more familiar language. The underlying ERPX software registers an admission, tracks its orders and charges, receives images and lab readings and keeps a single chart across locations. Those workflows still run when the AI assistance is removed. Radiologists also retain the browser viewer, comparison tools and digitally signed reporting as part of the imaging module.

BB on Autonomy and Oversight ModelThe oversight structure is described and one part is missing, commonly the threshold at which the system stops or what happens after it is wrong.
Vendor Published

The chart assistant proposes codes that the clinician can confirm, and the radiologist signs the finished report before it becomes a validated clinical result. PACS can then deliver the released report automatically through the patient and referring physician portals. The patient assistant can give a plain language interpretation of the readings while directing the patient back to their doctor. The reporting and chart workflows identify who confirms the clinical output. The patient assistant has no defined threshold for withholding an interpretation or sending it for clinical review.

BB on Model and Technology TransparencyThe approach or the suppliers are named without the version and update discipline behind them. Naming a supplier is the entry to this band both here and on Model Supply Chain Disclosure, which ask different questions of the same disclosure: who receives the data, and what produces the output.
Vendor Published

The physician workflow combines dictated material, draft chart documentation and suggested ICD 10 diagnoses, each marked as suggested by Davix. An advanced imaging viewer reconstructs studies in multiple planes and combines views, and the patient assistant compares current and prior lab values in a written explanation. Davix names AWS for cloud computing and lists Corti, a clinical speech and language provider, and Anthropic's Claude as technology partners.

It does not say which partner's model drives the documentation tools or the results assistant, and it has no model version or release history that would let a hospital trace a change in output to a model update.

BB on Model Supply Chain DisclosureSubstantial partial disclosure, or a chain that is structurally short: an in house build, a cleared model that cannot be quietly swapped, or a deployment where the transfer does not occur at all. Naming the model provider exits the band below into this one; the axis rises from here on the completeness of the party list and on the terms that govern data once it arrives.
Vendor Published

The image and record workflows run on AWS cloud infrastructure. Davix lists Corti and Anthropic's Claude as technology partners beside AWS, which puts names on the model layer behind its documentation and results assistants. PACS/RIS sends released studies to the provider and patient portals, and the patient assistant works with result values to generate a written explanation. The privacy terms allow sharing needed to deliver the service or comply with law. Davix does not tie either partner to a feature or state the retention and training terms that apply when clinical material reaches them.

CC on Clinical and Operational EvidenceNamed customers, or vendor reported percentages with no method, denominator or reference standard. Scale of use is recorded here and is not treated as evidence of benefit.
Vendor Published

Clínica ConfíaSalud, Hospital Regional Julio César Demarini, Clínica Internacional San Rafael and FaceClinic are among the facilities Davix names as customers. It counts more than 3.7 million images managed and claims turnaround cut by up to 40% and administrative time by 50% across centers that run the suite, with no facility, baseline or observation period. The radiology workflow covers order creation, study acquisition and delivery of the signed report.

The documentation assistant helps clinicians produce notes and code diagnoses, while the results assistant explains individual lab readings. The sample explanation shown to prospects describes a cholesterol value as falling from 314 to 314 mg/dL.

CC on AI Safety and PHI StewardshipGeneral assurances of privacy and security that do not answer the questions artificial intelligence raises: what is retained, what reaches a model, and what happens to it there.
Vendor Published

The platform encrypts data and controls access to records by user role. Patients use their own credentials to view studies and can share a secure link with a referring doctor. The imaging plan gives 12 months of immediate access to stored studies and offers nine years of historical image storage. The privacy terms allow sharing of contact and service usage information when necessary to deliver the service or comply with law. The terms give patients access and correction rights, with no retention or training commitment for the documentation and results assistants.

Regulatory and Compliance
CC on HIPAA and BAA PostureA status is stated but not supported: compliance is claimed, or business associate status stated, without the underlying document, including where the only privacy notice published covers the website rather than the service that handles patients. The mirror case grades here as well: a substantive privacy document that reaches the service, with no statement of business associate status anywhere and no scope position taken. One of the two elements the band above asks for is present, which is a grade below it and not a grade at the floor.
Vendor Published

PACS/RIS and HIS claim HIPAA compliance for software that holds clinical records and diagnostic studies. The platform limits chart and image access to authorized users and grants patients their own portal credentials. Its privacy terms permit necessary sharing to deliver the service or satisfy legal requirements and give users a route to access or correct their personal information. Davix makes no commitment to sign a business associate agreement covering the hosted modules and the patient results assistant.

DD on Security Certifications and Trust CenterControls are asserted with nothing independent behind them, or nothing is published. Read the note before concluding anything: this is the grade most often corrected on a second pass, because assurance material frequently sits on a parent domain or inside an old announcement rather than on the product pages.
Vendor Published

The imaging service encrypts network traffic with TLS and assigns distinct permissions to technicians, specialist readers and referring physicians. It records which user viewed, changed or reported on a study. The hospital system uses location and professional access controls for the shared chart. Both modules show an ISO 27001 mark beside HIPAA, DICOM and HL7 marks, as a compliance claim with no certificate, audited entity, scope or renewal date.

CC on FDA and Regulatory StatusNo device claim is made and the product is scoped accordingly. Most administrative and operational products sit here and are not penalized for it, because this axis grades the appropriateness of the positioning rather than possession of a clearance. A stated limit on use, such as research use only or a clause that the product gives no medical advice, beside marketing that sells the product for clinical decisions also sits here, with both quoted, because the buyer has to ask which one governs.
Vendor Published

The imaging module gives radiologists tools to compare and measure studies and sign their own reports under Peru's digital signature law. The patient assistant explains results in light of an individual's history. In one example it describes LDL as elevated in light of cardiovascular risk and offers possible next steps, alongside a warning that it does not replace professional medical advice. The chart assistant marks its ICD 10 codes as suggestions. The viewer, suggested diagnostic codes and individualized explanations are sold without a specific device authorization claim.

DD on AI Governance and Bias DisclosureNothing published on how model behavior is governed or tested. Multilingual operation with no subgroup performance sits here when the vendor markets recognition quality as a strength, because a caller the system failed to understand leaves no complaint and no record.
Vendor Published

The chart workflow has a clinician confirm suggested ICD 10 codes, and radiology permissions distinguish technicians, radiologists and referring physicians. The patient assistant provides its own explanations of laboratory values and reminds patients that a clinician gives medical advice. Those steps give patients and staff distinct roles within ERPX. The suite has no model review framework for how the two assistants perform across the different patient groups and health facilities that use those workflows.

CC on AI Liability and RecourseMechanisms exist that let someone challenge an output, such as audit trails, source traceability or review before commit, with nothing standing behind the output and no route for the harmed party.
Vendor Published

The radiology workflow ties a signed report to its physician and records viewing, editing and reporting activity. Patients have a right to correct their personal information by contacting Davix. The chart keeps suggested diagnosis codes editable before clinician confirmation. The platform terms provide the software as is and exclude indirect and consequential damages. An erroneous lab explanation does not trigger a specific patient remedy under that agreement.

Integration and Deployment
CC on EHR and Interoperability DepthIntegration is claimed through standards or a middleware layer with no system named and nothing to verify.
Vendor Published

The radiology worklist passes scheduled patient information to imaging equipment and receives X ray, CT, ultrasound and MR studies in DICOM. ERPX also connects to external laboratory analyzers and existing systems through HL7 and FHIR. Inside the suite, PACS/RIS receives orders generated during admission in Davix HIS, and the chart brings together lab results and images after the modules process the orders. The hospital record and diagnostic modules share one login. No third party EHR is named as connected.

CC on Deployment Model and Data ResidencyA single hosted option with location implied rather than committed.
Vendor Published

PACS/RIS and the hospital record run in a browser with no servers at each facility, on AWS, with 99.9% availability promised. Authorized staff reach images and reports from multiple locations. Storage tiers distinguish studies kept for 12 months of immediate access from nine years of historical material. Remote readers can compare images and report from the same application, and patients can view a result on a phone. Davix commits neither the hospital record nor the AI processing to a country or cloud region.

Commercial
BB on Commercial TransparencyA price or a pricing basis is published without full tiers, so a buyer can size the cost before making contact.
Vendor Published

PACS/RIS carries monthly minimums of $53, $211 and $475 for Essential, Professional and Enterprise, set for volumes from 150, 500 and 1,000 studies, with a custom plan above 1,500. A standard CT study is $0.89, $0.76 or $0.63 across those tiers, and a plain X ray $0.25, $0.21 or $0.18. Activation is a one time $563, discounted to $450, $366 and $281 by tier. The clinical record module starts at a $47 monthly minimum for 500 encounters and up to five users. Every plan button opens a 45 minute sales demo. The price schedule sets an 18 month minimum contract, while the imaging module is advertised with no lock in.

CC on Setting and Specialty CoverageCoverage is claimed broadly without specifics, or stated clearly with nothing validating it yet.
Vendor Published

The suite covers radiology, laboratory and hospital record workflows across multiple facilities. Radiology staff can use the same worklist and reporting flow for X rays, CT, ultrasound and MR studies. Referring physicians follow their orders from acquisition through report delivery, and sites offering teleconsultations can open the complete record during a remote visit. Patients can book an appointment and view results from the portal. Those are specific workflows for diagnostic centers and hospital networks, while the AI assistance has no measured performance by specialty or care setting.

Alternatives

Alternatives to Davix

Other products that do the same kind of work as Davix, and what each one does.

RadioView.AI is an enterprise imaging and reporting platform from NeuroCareAI, which trades as SaveLife.AI. Radiology departments and teleradiology groups use one worklist for studies from multiple sites.

WA Solutions sells WAStockID to ambulatory surgical centers, aesthetic practices, medical spas and clinics. Staff use a phone or tablet to receive shipments, record supplies used during procedures, transfer stock and complete counts.

YouShift sells scheduling software for physician groups and hospital departments. The scheduling engine produces options from coverage requirements, contract hours, rest rules, clinician eligibility and staff requests.

New Lantern sells a cloud based radiology platform that replaces a practice's PACS, worklist and reporting software with one browser workspace.

Saince Prava is an enterprise PACS with a built in clinical AI suite and advanced 3D visualization, sold to hospital radiology departments by Saince, Inc. of Alpharetta, Georgia, the clinical documentation company behind the Srava ambient scribe.

SARC MedIQ sells a cloud PACS with AI assisted reporting to outpatient specialty practices, led by cardiology and vein care, with pages for vascular, radiology, orthopedic, OB-GYN, pain medicine and podiatry practices.

Commercial

Pricing

Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.

Entry Price Pricing Basis BAA Tier Implementation Source
$47 monthly minimum for HIS
$47 baseline
HIS has monthly minimums of $47, $83 and $175 at 500, 1,000 and 2,500 encounters, with per encounter rates of $0.141, $0.119 and $0.100. PACS/RIS starts at $53 a month for 150 studies and up to five users. Professional is $211 and Enterprise is $475, with modality specific rates. Standard CT runs $0.89, $0.76 or $0.63 by tier. — The three published tiers carry promotional one time activation charges of $450, $366 and $281. Custom activation and implementation are part of the quote. Vendor Published

Plan activation opens a sales demo. The PACS price schedule states a minimum of 18 months. The imaging module describes its plans as having no fixed term. The minimums and per use figures exclude local taxes.

Contact us

Found a vendor we missed? Have feedback on the index? We’d love to hear from you.