Diagnostics & Genomics
B

Belun Technology

Belun Technology, founded in 2016 with headquarters in Hong Kong and Singapore and research and development in Taiwan, sells a ring based home sleep apnea test. The Belun Ring, worn on the base of the index finger, records oxygen saturation, beat to beat pulse, photoplethysmography and movement for up to 10 hours a night, and Belun Sleep AI, deep learning software trained on more than 200 million polysomnography data segments, turns those signals into an apnea hypopnea index, three stage sleep staging of wake, REM and non REM, and a report on autonomic response. The homepage also lists AHI at 3% and 4% desaturation thresholds and hypoxic burden, with multi night testing and manual scoring for clinicians, and a three night report ready within 10 minutes.

FDA cleared the Belun Sleep System BLS-100, the ring with its AI software, under K222579 in February 2023 to aid in evaluating moderate to severe sleep related breathing disorders in adults suspected of sleep apnea, in clinical and home settings under a clinician's direction. In the clearance study of 106 patients scored against polysomnography, the system reached 87.7% accuracy, 89.8% sensitivity and 86.0% specificity at an AHI cutoff of 15. Belun cites published work on shorter sleep apnea waiting lists, from 104 to 45 weeks, and on oral appliance titration, and works with clinical partners in the United States, Singapore, India, Australia, Taiwan and five other markets. The ring also holds Taiwan FDA and Thailand FDA clearances, and the company is ISO 13485 certified. In Hong Kong the three night test is also sold direct to consumers, at HK$1,600 including tax.

AI Health Index verifiedNovember 22, 2026
Compare Belun Technology with other vendors
Founded
2016
Headquarters
Hong Kong and Singapore
Website
beluntech.com/
Categories
diagnostics-and-genomics
Indexed Products
Belun Sleep System BLS-100, Belun Sleep AI, Belun Ring
Buyer Segments
Sleep Clinics and Sleep Physicians, Dental Sleep Medicine Practices, Cardiology and Primary Care Clinics
Assessment

Capability Axes

An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read

AI Capability
BB on AI CentralityThe model is the engine of a core module. The platform carries other value, but this capability does not exist without it.
Regulatory Filing

The sleep apnea result comes from the model. Belun Sleep AI, the standalone analysis software in the cleared system, applies deep learning to the ring's oxygen saturation, pulse, photoplethysmography and movement signals to produce the apnea hypopnea index and sleep stages, trained on more than 200 million polysomnography data segments, and the diagnostic report is built from its output.

The Belun Ring underneath is a medical grade oximeter that FDA cleared on its own before the AI system, and it still delivers oxygen saturation, pulse rate and heart rate variability with the model removed. The software is the engine of the sleep apnea test, while the hardware carries measurement value of its own.

BB on Autonomy and Oversight ModelThe oversight structure is described and one part is missing, commonly the threshold at which the system stops or what happens after it is wrong.
Regulatory Filing

A clinician sits on both ends of the US test. The system is prescribed by a healthcare professional and cleared for use under a clinician's direction in clinical and home settings, to aid evaluation rather than to diagnose on its own. Reports go to the clinic's inbox for review with the patient, and the platform offers manual scoring beside the AI result, so a sleep physician can rescore a night before acting on it.

The homepage sells it as the "World's first AI-powered wearable ring system for OSA diagnosis", wider than the cleared aid in evaluation, and in Hong Kong the three night test is sold straight to consumers, with a report and a debriefing session and no prescription mentioned. Belun states neither what the software does with a poor signal night, nor the confidence below which it withholds an index, nor how a scoring error found later is corrected.

BB on Model and Technology TransparencyThe approach or the suppliers are named without the version and update discipline behind them. Naming a supplier is the entry to this band both here and on Model Supply Chain Disclosure, which ask different questions of the same disclosure: who receives the data, and what produces the output.
Regulatory Filing

The approach is named. Belun Sleep AI uses deep learning on photoplethysmography, oxygen saturation, pulse rate, heart rate variability and actigraphy, trained on more than 200 million polysomnography data segments, and its hypopnea scoring is tuned to the AASM 1B rule, which counts a 4% desaturation. The FDA summary separates the ring from the standalone analysis software and names its two outputs, bAHI and bSTAGES. Belun cites a 2023 Sleep Health paper behind its deep learning claims. The software version the clearance covers is not given, and the product has no release history or change notice, the 3% threshold index and hypoxic burden on the homepage included.

BB on Model Supply Chain DisclosureSubstantial partial disclosure, or a chain that is structurally short: an in house build, a cleared model that cannot be quietly swapped, or a deployment where the transfer does not occur at all. Naming the model provider exits the band below into this one; the axis rises from here on the completeness of the party list and on the terms that govern data once it arrives.
Regulatory Filing

The chain is short by construction. Belun builds the ring and the deep learning software itself, and the scoring model is part of a cleared device, so it cannot be swapped for another provider's model without a new regulatory submission. The FDA summary describes the analysis software as standalone PC software that loads data exported from the ring's cradle, which stores up to 120 hours. No cloud service, language model or analytics vendor is named. The email delivery of reports to clinics implies a service run by Belun or a host, with no operator, hosting company or subprocessor list given for that report path.

BB on Clinical and Operational EvidenceNamed deployments with dated outcome figures and enough method to test them, or published research short of independent validation.
Regulatory Filing

The clearance study enrolled 106 adults suspected of obstructive sleep apnea and compared the system with overnight polysomnography scored blind under AASM version 2.4 rules and reviewed by a board certified sleep physician: 87.7% accuracy, 89.8% sensitivity and 86.0% specificity at an AHI of 15, and 92.5%, 84.0% and 95.1% at 30. Staging across 85,471 epochs reached 90.8% accuracy for REM and 82.7% for non REM, and total sleep time differed by 21.8 minutes on average.

One sleep laboratory is described. Belun also cites peer reviewed work: a 2023 Respirology study of waiting time falling from 104 to 45 weeks, a 2023 Sleep Health paper and dental sleep medicine studies of multi night testing and oral appliance titration.

DD on AI Safety and PHI StewardshipNothing published on how protected information moves through the system.
Vendor Published

The ring stores up to 10 hours a night, the cradle holds up to 120 hours, the analysis software loads the exported data, and an HSAT report reaches the clinic's inbox, three nights ready within 10 minutes. The homepage's privacy policy link is a placeholder that opens no policy, so nothing in writing covers how sleep recordings and reports are stored, how long they are kept, who can see them, or whether recordings feed further training of a model built on more than 200 million polysomnography segments. De identification and the protection of emailed reports are not addressed, and the Hong Kong consumer test returns its report to the sleeper directly.

Regulatory and Compliance
DD on HIPAA and BAA PostureNo statement of status and no privacy document that reaches the product. Both halves are absent at this grade: a service level privacy document on its own lifts a vendor to the band above even where no status is stated. A website privacy notice, including one that says it does not cover customer data, does not reach the product, so a vendor whose only document is that notice and who states no status grades here.
Vendor Published

No HIPAA statement, business associate role or BAA appears for the system, and the homepage's privacy policy link is a placeholder, so no privacy document reaches the product. Belun is a Hong Kong and Singapore company with a US hotline and US WhatsApp line, clinical partners in the United States and FDA clearance for US sale, and its report service emails sleep test results to clinics. A US sleep practice that prescribes the ring gets no written terms on how the overnight recordings and reports its patients generate are handled, stored or shared.

DD on Security Certifications and Trust CenterControls are asserted with nothing independent behind them, or nothing is published. Read the note before concluding anything: this is the grade most often corrected on a second pass, because assurance material frequently sits on a parent domain or inside an old announcement rather than on the product pages.
Vendor Published

Belun holds ISO 13485 certification for its quality management system, a medical device manufacturing standard rather than an audit of information security, and the ring is cleared as a medical device in the United States, Taiwan and Thailand. The ring, the analysis software and the report service that emails results to clinics come without a SOC 2 report, ISO 27001 certificate, HITRUST assessment, penetration test or trust center.

Belun states no security controls, encryption or access model for the overnight sleep data, the cradle's up to 120 hours of stored recordings or the emailed reports. Support runs through WhatsApp lines for Hong Kong and the United States and two hotlines, with no rules given for how patient information is handled on them.

BB on FDA and Regulatory StatusThe pathway is stated and in progress, or a clearance is named without the vintage and scope a buyer needs to match it to the product on offer. A product outside device regulation also sits here when the vendor publishes what it is for and in what setting and the product on offer matches, or names another regime it works under, such as a registration outside the United States. A general clause saying the service is not medical advice does not reach this band.
Regulatory Filing

FDA cleared the Belun Sleep System BLS-100 under K222579, decided in February 2023 under 21 CFR 868.2375, product code MNR, as a wearable that records, analyzes, displays, exports and stores parameters to aid in evaluating moderate to severe sleep related breathing disorders in adults suspected of sleep apnea, under a clinician's direction. The cleared outputs are the apnea hypopnea index and sleep staging.

The homepage sells more: AHI at both 3% and 4% thresholds where the cleared algorithm follows the 4% rule, hypoxic burden, autonomic response, a system for OSA diagnosis, and uses in insomnia and oral appliance titration, under a banner of FDA cleared AI software. The ring also holds Taiwan FDA Class II and Thailand FDA Class III clearances.

CC on AI Governance and Bias DisclosureResponsible artificial intelligence is committed to in policy language with no evaluation behind it. Most of the index sits here.
Regulatory Filing

The model was tested under the device regime: the clearance study compared it with blind, physician reviewed polysomnography in 106 adults and reported accuracy by AHI cutoff and by sleep stage. No results are reported by sex, age, body mass index or skin tone, which matters for a photoplethysmography and oxygen saturation device, and the single laboratory study population is the only one described.

Wake detection sensitivity was 60.4%, the weakest figure in the summary, with no breakdown of where it falls short. Belun offers no bias evaluation, subgroup comparison or governance framework beyond its quality certification.

BB on AI Liability and RecourseA published falsifiable commitment, or a real correction route the affected person can exercise against the vendor. A published error rate with its method and denominator grades here. A statutory right that runs to the covered entity rather than to the vendor does not reach this band on its own: every other route here asks something of the vendor, and being located in a particular jurisdiction is not conduct.
Regulatory Filing

Error rates are on record with their method and denominator. The FDA summary reports sensitivity and specificity for the AI's apnea hypopnea index at AHI cutoffs of 15 and 30 in 106 patients against blinded polysomnography, epoch level accuracy for each sleep stage across 85,471 epochs, and the mean and absolute error in total sleep time. Clinicians can rescore nights manually, and the system aids evaluation under professional direction rather than replacing it. No warranty, remedy or correction route for a missed or overstated apnea index runs from Belun to a clinic or patient, and the sale runs under no terms a clinic can read in advance.

Integration and Deployment
DD on EHR and Interoperability DepthNo integration evidence. A connector described as available on request grades here until one exists.
Vendor Published

Reports leave the system as files and email. The cleared system records, analyzes, displays, exports and stores the data, the ring docks in a cradle for upload and charging, the analysis software runs on a PC, and clinics receive an HSAT report in their inbox with three nights processed within 10 minutes. No EHR, sleep laboratory scoring system, practice management system or interface standard such as HL7, FHIR or EDF export is named, and no connector or marketplace listing appears. The homepage says the platform supports both individual wellness management and professional medical workflows, without saying what connects to it.

CC on Deployment Model and Data ResidencyA single hosted option with location implied rather than committed.
Regulatory Filing

The cleared system is a ring, a charging cradle that holds up to 120 hours of data, and Belun Sleep AI as standalone PC software that loads the exported recordings, per the FDA summary. The homepage adds a report service that sends three night results to a clinic's inbox within 10 minutes, which implies processing outside the clinic's PC.

Where that service runs, in which country recordings and reports are stored, and how one clinic's data is separated from another's are not given, for a company headquartered in Hong Kong and Singapore with research and development in Taiwan.

Commercial
CC on Commercial TransparencyNo price is published and the posture is discoverable: a buyer can establish how the product is sold and what drives the cost before contacting the vendor. Most of the index sits here.
Vendor Published

Belun sells professional sleep tests as trade solutions through contact, with a demo request, a partner form, WhatsApp lines for Hong Kong and the United States and two hotlines as the routes in, and the ring is called "easy to use, affordable with medical accuracy" with no figure.

The one listed price is consumer: in Hong Kong only, the Home Sleep Test Service costs HK$1,600 including tax for three nights, with the ring delivered and collected and a sleep report and debriefing afterward, and the listing currently shows it sold out. That sets the unit as a three night test, while a US clinic's cost for rings, the analysis software or the report service has no figure.

BB on Setting and Specialty CoverageCoverage is named with validation behind part of it.
Regulatory Filing

The cleared setting is precise: adults 22 and older suspected of moderate to severe sleep related breathing disorders, tested in clinical or home settings under a clinician's direction, and the clearance study supports that population at AHI cutoffs of 15 and 30.

Belun markets wider: multi night testing for mild sleep apnea, oral appliance titration in dental sleep medicine, insomnia sleep diaries for psychologists, and cardiology and psychiatry partners, with clinical partners in ten markets including the United States, Singapore, India and Australia, and in Hong Kong the test is also sold straight to consumers. Published dental sleep medicine work covers part of that range, while the mild disease and insomnia uses rest on the company's own framing.

Alternatives

Alternatives to Belun Technology

Other products that do the same kind of work as Belun Technology, and what each one does.

Beacon Biosignals records and analyzes brain activity for sleep diagnostics and drug development.

aetherAI sells aetherSlide, a system hospital pathology departments use to manage and review scanned slides, along with its own AI for bone marrow smears and colonoscopy. aetherSlide holds FDA clearance (K233126, 2024), Taiwan approval and CE marking, and is named at hospitals in Taiwan…

AccurKardia makes AccurECG, cloud based software for automated interpretation of ambulatory ECG recordings, sold to cardiac monitoring companies, device manufacturers, hospitals and independent diagnostic testing facilities.

Cytovale makes IntelliSep, an FDA cleared blood test that estimates the probability of sepsis in adults with signs of infection in the emergency department by measuring how their white blood cells deform.

Allelica, based in San Francisco, builds polygenic risk scores and sells them several ways.

Anumana builds neural network software that reads a standard 12 lead ECG for heart disease the trace does not visibly show, so a health system can find patients earlier from a test it already runs.

Commercial

Pricing

Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.

Entry Price Pricing Basis BAA Tier Implementation Source
Clinics quoted on request; Hong Kong consumer test HK$1,600
Belun sells the Belun Ring with its cleared Belun Sleep AI software and report service to clinicians and partners as trade solutions quoted on contact. Its one listed price is consumer: a Hong Kong only Home Sleep Test Service at HK$1,600 including tax for three nights, with the ring delivered and collected and a report afterward. No business associate terms are listed. Clinics receive rings, charging cradles and the analysis software, with three night reports returned within 10 minutes. No setup or training fee is listed. Vendor Published

Routes in are a demo request, a partner form, WhatsApp lines for Hong Kong and the United States and two hotlines, and professional sleep tests are sold as trade solutions through contact. Whether a clinic buys rings, leases them or pays per study is settled in that contact.

Contact us

Found a vendor we missed? Have feedback on the index? We’d love to hear from you.