B-Secur
B-Secur licenses HeartKey, a family of electrocardiogram analysis libraries for medical device companies and cardiac monitoring platforms. HeartKey Rhythm takes recorded single lead ECGs from compatible ambulatory patches, Holter monitors and event recorders. It filters noise, rates signal quality, detects beats and returns rhythm findings such as atrial fibrillation, pauses and ventricular ectopy. The API can return the onset and duration of rhythm episodes, heart rate summaries and the share of a recording spent in a rhythm. Trained staff review the output before a physician uses it in diagnosis.
B-Secur supplies a container for deployment within the integrator's environment. The API accepts EDF and CSV recordings and can deliver results by webhook for processing that runs after a request returns. The original HeartKey library also supports short ECG spot checks on compatible devices. HeartKey Wellness and HeartKey ID use the ECG signal for wellness measurements and identity checks. The evaluation web app displays the analysis on a sample recording ahead of an integration. Alongside the software, B-Secur sells ECG engineering services in three packages that run from design assessment to a submission ready technical file.
Alan Foreman and Adrian Condon cofounded B-Secur in Belfast. The company counts more than 2 million hours of ECG data and 7 billion heartbeats analyzed. In January 2025, B-Secur and Biotricity announced that they would combine HeartKey analysis and Biotricity's ambulatory monitoring devices for providers and independent diagnostic testing facilities. A July 2026 collaboration with CSEM pairs the ECG software with optical sensing for wearable manufacturers, and an October 2026 pilot with Beacon Hospital Research Institute brings ECG data from consumer wearables into clinical care.
Capability Axes
An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read
HeartKey Rhythm labels rhythm episodes and classifies beats in recorded ECGs. Its beat and rhythm analysis combines rules based calculations with machine learning, and the released software is compiled and static, so the classifiers do not change after deployment. A separate signal processing engine conditions the waveform and detects QRS complexes. The output includes ventricular ectopic beats and burden measures that the licensee's software passes to a clinician's display.
Noise reduction, signal quality scoring and the 30 second spot check in HeartKey Core run on signal processing, so the learned classification is the engine of the Rhythm library and one part of the wider suite.
Rhythm identifies beat and rhythm events and returns a signal quality assessment with the recording. The integrating system is obliged to notify users when data is corrupted. Trained medical staff review the analysis, and a physician interprets the rhythm alongside patient history and other findings. The library is advisory, is not built for real time patient monitoring or cardiac alarms and cannot detect myocardial infarction.
Queueing an episode for a person and recording a corrected finding happen in the licensee's application, which owns the review queue. Signal quality arrives at the API boundary, and the thresholds for routing an episode to a reviewer are the licensee's to set.
HeartKey Rhythm separates signal conditioning, beat detection and signal quality from the arrhythmia functions. Beat and arrhythmia classification combines signal processing, rules and machine learning in compiled software that does not change after deployment. The API has distinct endpoints for filtering and analysis, and a change log ties functions and fixes to numbered releases from 1.0.0 in March 2023 to 4.3.0 in May 2025. A version endpoint confirms which release answered a request.
The conditioned ECG is not meant as input for other automated analysis, since filtering can distort some ventricular ectopic beats. The training data behind the learned classifiers has not been characterized, and the 1,200 ECG comparison set served clearance testing only.
B-Secur developed HeartKey's signal processing engine and its rhythm analysis library itself, so the analysis calls no outside model provider. The container runs on the customer's own infrastructure, which keeps ECG processing inside the environment the integrator selects. Google Cloud distributes the container through an artifact registry and is one of three supported deployment platforms, with Amazon Web Services and Azure. B-Secur operates account authorization for HeartKey accounts. Its own cloud API runs on a host it has not named.
HeartKey Rhythm went through bench testing against reference annotations from standard ECG databases and a proprietary set of more than 1,200 ECGs, about two thirds of them recorded in the United States. Sensitivity, specificity and positive predictive value met the acceptance criteria set for the device, with no numeric results released.
Separate research on digital denoising tested clinician interpretation of conditioned ECGs, and a wrist wearable study measured atrial fibrillation detection on 30 second recordings. B-Secur counts more than 2 million hours of ECG data and 7 billion heartbeats analyzed. Biotricity named HeartKey for its ambulatory monitoring platform in January 2025, and Beacon Hospital Research Institute opened a pilot in October 2026 that brings wearable ECG data into clinical care. Neither has reported a measured result.
HeartKey Rhythm processes a recording and does not store patient data after processing. The API accepts ECGs as files, raw samples or a download reference, and a request that finishes later is answered at the integrator's own webhook. Customer run deployments keep the processing software inside the integrator's environment. An audit log tracks processing requests, and the integrator manages its own clinical users.
The released classifiers are compiled and static, so production recordings do not change them. The no storage commitment has no companion rule on deidentification or on training later versions with licensed ECG inputs.
HeartKey Rhythm's production integration sits inside an ECG application the licensee operates. The integrator manages its physicians and patients and holds a separate account with B-Secur for the API. Requests carry ECG recordings and hardware parameters, so a clinical integration can send patient information to the hosted service. B-Secur acts as controller for website contacts and account administration under UK and EU data protection law, and that privacy notice stops at the website. B-Secur states no business associate status for the hosted API and offers no BAA ahead of the license agreement.
Account setup and token management govern access to the HeartKey Rhythm API, with bearer tokens, token revocation and request logging for the integrating system. Customer run deployments follow guidance on Kubernetes security, network controls, storage integrity and monitoring. The Rhythm clearance included software cybersecurity testing to IEC 81001-5-1 that found no vulnerabilities.
B-Secur holds ISO 13485:2016 certification for medical device quality management, dated 2023 with certificate number SCAR-14.1.1.0. That certificate audits the quality system, and B-Secur cites no SOC 2 or ISO 27001 audit of how the production API is operated.
The original HeartKey software library was cleared under K200884 in December 2020 for 30 second single lead spot checks in adults, classifying a recording as normal sinus rhythm, atrial fibrillation, bradycardia or tachycardia, or returning it as inconclusive or too poor to read.
K233755 cleared HeartKey Rhythm in August 2024 for advisory analysis of recorded adult ambulatory ECGs from compatible Holters, patches and event recorders, covering signal conditioning, signal quality, QRS and ventricular ectopic beat detection and rhythm analysis. Real time ECG monitors, cardiac alarms and over the counter devices are excluded. B-Secur's product matrix marks Rhythm and Core as FDA cleared and Wellness and ID as meeting other standards.
The suite is also sold as 510(k) cleared for “spot-check or continuous monitoring” with neither clearance number nor the recorded analysis limit beside it, and a footnote places Wellness and ID in the Edge library under K200884, whose indication covers neither.
HeartKey Rhythm was tested on a proprietary set of more than 1,200 ECGs in addition to standard reference databases. About two thirds of the proprietary recordings came from the United States. Sex was recorded for half of the set, split evenly between women and men, and race for about 40%, with 16% of the set White and 24% non White.
Rhythm sensitivity, specificity and positive predictive value were measured against the device's acceptance criteria for the whole set, with no results by group. B-Secur presented a study of ECG analysis across racial and ethnic groups at ESC Congress 2025, and its findings are open to congress registrants only.
HeartKey Rhythm returns the conditioned recording, event details and the quality data that trained staff use to review the output. The integrator must surface corrupted data to users and has request audit logs to trace what was processed. Clinical interpretation stays with the physician, and findings can be checked against the source ECG in the receiving application.
The safety instructions caution that filtering can distort some ventricular ectopic beats, so the original recording matters when a reading is challenged. A disputed interpretation runs through the licensee's clinical review. B-Secur offers no warranty, error rate or correction route for a wrong classification ahead of the license agreement.
The HeartKey Rhythm API accepts raw samples in JSON and EDF or CSV recordings along with the device configuration, up to 500 MB a request. It returns ECG results in structured responses and completes long requests through a webhook. The library is built into ECG management and remote monitoring systems, which supply the display and the patient workflow. Biotricity pairs the algorithms with its ambulatory devices, and CSEM pairs them with optical sensing for wearables. The interface carries the recording and its analysis only. Writing a finding to a patient chart is the job of the monitoring or diagnostic platform around it.
The HeartKey Rhythm library runs in a licensee's local environment or on infrastructure the licensee controls, as a container on x86-64 servers running Ubuntu 22.04. Kubernetes deployments are supported on Google Cloud, Amazon Web Services and Azure. The integrator chooses where its application and ECG data run, and HeartKey Rhythm discards patient data after the processing step. B-Secur handles account authorization through a separate endpoint. Stored ECGs and reports are isolated by the customer's own infrastructure controls. The hosted cloud API comes without a region or tenancy commitment.
HeartKey is sold as a licensed library. B-Secur provisions an account for production API access, and device makers either call the hosted service or run the container on their own infrastructure. Usage is metered against limits written into the license. The evaluation web app runs the algorithms on sample recordings before an integration.
Engineering work is sold in three cumulative packages: ECG Assess for design and regulatory planning over about 8 weeks, ECG Prove through prototype evaluation over about 26 weeks and ECG Complete through clinical work and a submission ready technical file over about 52 weeks. Assess and Prove are discounted 12% and 25% against buying their stages singly. License rates and package prices come by quote, and most engagements open with a 30 minute call.
HeartKey Rhythm processes adult ambulatory ECGs for trained staff working with compatible Holter monitors, extended Holters, patches and event recorders. It reads a single lead from recordings of 20 seconds to 24 hours sampled at 125 to 500 Hz, and it needs at least two minutes of signal for an atrial fibrillation finding. Pediatric records and recordings from patients with pacemakers are excluded.
HeartKey Core covers the second use, a 30 second spot check inside another manufacturer's device, with its own test data for compatible lead and electrode configurations. The Rhythm testing used reference annotated ECGs, most of them collected in the United States. Health systems and independent diagnostic testing facilities are the intended settings for the Biotricity collaboration, which has reported no deployment results.
Alternatives to B-Secur
Other products that do the same kind of work as B-Secur, and what each one does.
AccurKardia makes AccurECG, cloud based software for automated interpretation of ambulatory ECG recordings, sold to cardiac monitoring companies, device manufacturers, hospitals and independent diagnostic testing facilities.
PulseAI is an ECG analysis company in Belfast, Northern Ireland, that licenses deep learning models to read electrocardiograms from smartwatches, ambulatory patches, 12 lead machines and defibrillators, on the device or in the cloud.
Eko Health makes digital stethoscopes and FDA cleared software that analyzes heart sounds and a single lead ECG recorded during a routine exam, for primary care clinicians and health systems that want to find heart disease earlier.
iRhythm runs Zio, a long term ambulatory cardiac monitoring service.
Beacon Biosignals records and analyzes brain activity for sleep diagnostics and drug development.
Healthcare information technology company (NASDAQ: HSCS) selling ECG management software to hospitals and practices.
Pricing
Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.
| Entry Price | Pricing Basis | BAA Tier | Implementation | Source |
|---|---|---|---|---|
|
Contact B-Secur
|
HeartKey Rhythm is licensed for production integration into an ECG device or cardiac monitoring platform. B-Secur provisions production API access and meters usage against limits written into the license. Rates come by quote. | Business associate terms are a production contracting matter for HeartKey deployments that process patient data. | ECG Assess, ECG Prove and ECG Complete cover design, validation and integration at successive project stages over about 8, 26 and 52 weeks. Assess and Prove are discounted 12% and 25% against buying their stages singly, and each package is quoted for the device program. | Vendor Published |
The HeartKey web app is an evaluation tool with its own access terms. A representative handles the software license for an embedded or hosted deployment.