Healthcare Cybersecurity
C

Cynerio

Cynerio secures the connected devices inside hospitals, and it was built for healthcare from the outset rather than adapted to it. Founded in 2017 and based in New York, with Samsung NEXT among its investors, it was acquired by the asset management company Axonius in July 2025 for a reported figure above 100 million dollars and now operates inside that platform. Anyone searching for Cynerio is looking at an Axonius business.

The platform has three parts. Network detection and response for healthcare uses deep packet inspection and behavioural anomaly detection to identify threats on clinical networks in real time. Medical device security discovers connected devices automatically, assesses their risk and offers mitigation through micro segmentation and patching. Complete asset visibility maintains a single inventory across information technology, operational technology and connected medical devices with compliance reporting.

Two things distinguish it from its peers. In 2021 it released an attack detection and response module that goes beyond inventory to containment, letting a hospital quarantine a device showing malicious behaviour immediately while deferring full remediation until the device is not in use, so that a patient connected to it is not affected. And its patient data security module is data centric rather than device centric: it identifies where electronic protected health information is exposed across clinical systems, maps data flows between devices and external parties, and monitors access patterns.

The company co produced research with the Ponemon Institute, surveying leaders at 517 United States health systems, which found that 71 percent rated connected device risk as high or very high while only 21 percent described their protections as mature, and reported that organisations suffering cyberattacks saw increases in bed days, mortality, affected procedures, transfers and complications. That work is now cited in the professional literature on medical device security.

It integrates with Microsoft Sentinel, belongs to the Microsoft Intelligent Security Association, and sells through managed security providers as well as directly.

AI Health Index verifiedAugust 8, 2026
Compare Cynerio with other vendors
Founded
2017
Headquarters
New York, New York
Website
www.cynerio.com
Categories
healthcare-cybersecurity, hospital-operations
Assessment

Capability Axes

An AI Health Index grade measures what a buyer can verify from public sources on the date shown. It is not a rating of how good the product is. A vendor can build an excellent system and grade low on an axis because it publishes nothing an outsider can check. How grades read

AI Capability
BB on AI CentralityThe model is the engine of a core module. The platform carries other value, but this capability does not exist without it.
Vendor Published

Two of the three parts rest on models. Identifying what a device is from passive network traffic alone is a classification problem, since a clinical device announces itself inconsistently or not at all, and detecting an attack by behavioural anomaly means learning what normal looks like for that device type and flagging departures from it.

The third part is engineering rather than inference. Micro segmentation, policy enforcement and inventory reporting are network work that would function with far less intelligence behind it, and much of the buyer's day to day value sits there. That mix holds the grade at B.

BB on Autonomy and Oversight ModelThe oversight structure is described and one part is missing, commonly the threshold at which the system stops or what happens after it is wrong.
Vendor Published

The autonomy is real and the design around it is unusually thoughtful, which deserves saying plainly.

The system can quarantine a device that is behaving maliciously, immediately and without waiting for a person. In a hospital that is a consequential act, because the device may be attached to a patient. The company's stated answer is to separate containment from remediation: isolate the device at once so it cannot spread or be driven, then perform full remediation only when the device is not in use. That is clinical safety reasoning applied to a security control, and very little security tooling is built that way.

Held at B because nothing published states what a false positive costs in practice, whether containment can be configured to require human approval for particular device classes, or how a biomedical engineering team is notified when a device is isolated mid shift.

CC on Model and Technology TransparencyThe architecture is described in general terms with nothing identified. Proprietary is asserted rather than explained.
Vendor Published

The mechanisms are named at a useful level: passive analysis, deep packet inspection, behavioural anomaly detection, micro segmentation, and a stated ability to operate from the first day of deployment rather than after a long learning period.

What is absent is any measure of how well the detection works. No detection rate, no false positive rate, and no description of how device classification is validated, which matters because misidentifying a device type propagates into the risk score and the segmentation policy built on top of it.

CC on Model Supply Chain DisclosureThe architecture is described and no provider is named.
Vendor Published

The mechanisms are named at a useful level and the exposure they create is structural, which is the substantive point on this record. Passive analysis, deep packet inspection, behavioural anomaly detection and micro segmentation are each identified, with a stated ability to operate from the first day rather than after a long learning period, so a buyer can reason about what the system does.

Deep packet inspection on a clinical network means the platform sees the traffic on that network, and clinical network traffic carries patient information moving between devices and systems. One module is built explicitly on that capability, mapping where protected health information is exposed and monitoring access patterns.

So the tool that finds the exposure is itself positioned to see everything exposed, which is a legitimate design and an unavoidable one for the function, and it makes the vendor a party with unusually broad visibility rather than a narrow integration. What is absent is what follows from it.

Nothing published states what the platform retains from what it inspects, whether payloads are stored or only metadata and derived signals, how long anything persists, who at the vendor can reach it, or whether any of it leaves the customer environment. No model, hosting arrangement or sub processor list was located either. Ask what is retained from inspected traffic, in what form, and who can access it.

CC on Clinical and Operational EvidenceNamed customers, or vendor reported percentages with no method, denominator or reference standard. Scale of use is recorded here and is not treated as evidence of benefit.
Third Party Estimated

The company's best known research establishes the size of the problem rather than the effect of the product, and the distinction matters.

With the Ponemon Institute it surveyed leaders at 517 United States health systems and reported that 71 percent rated connected device risk as high or very high while only 21 percent considered their protections mature, alongside reported increases in bed days, mortality, affected procedures, transfers and complications among organisations that suffered attacks. That work is now cited in the professional literature, which is a real external marker, and it is survey research commissioned by an interested party measuring the market's condition rather than the vendor's effect on it.

No published deployment outcome, detection performance or before and after comparison at a customer was located. Acquisition by a larger platform for a reported sum above 100 million dollars is a market judgement rather than a clinical one.

CC on AI Safety and PHI StewardshipGeneral assurances of privacy and security that do not answer the questions artificial intelligence raises: what is retained, what reaches a model, and what happens to it there.
Third Party Estimated

Graded on an honest basis, and the exposure here is structural rather than incidental.

A product that performs deep packet inspection on a clinical network sees the traffic on that network, which includes patient information moving between devices and systems. One module is explicitly built on that capability, mapping where protected health information is exposed and monitoring access patterns. So the tool that finds the exposure is itself positioned to see everything exposed.

That is a legitimate design and it raises the obvious question, which is what the platform retains from what it inspects, whether payloads are stored or only metadata, and who at the vendor can reach it. Nothing published answers it.

Regulatory and Compliance
CC on HIPAA and BAA PostureCompliance is claimed without the underlying document, or the published privacy notice covers the website rather than the service that handles patients.
Third Party Estimated

Graded on an honest basis. No compliance statement or agreement posture was located in this pass.

The acquisition adds a question a buyer should ask directly rather than assume: whether the agreement now sits with the acquiring platform, what changed in it, and whether data collected under the original arrangement is available to the wider business.

CC on Security Certifications and Trust CenterControls are described with an outside check behind them, such as independent penetration testing on a stated cadence, but no attestation against a recognised framework.
Third Party Estimated

Recorded honestly and provisionally: the dedicated trust and security search this index requires was not run in this pass, and no attestation was encountered incidentally.

That gap is worth flagging without irony rather than with it. A security vendor's own certifications are ordinarily among the easiest things to find, and a buyer evaluating a product that will sit on the clinical network with visibility into everything should insist on seeing them before anything else. Membership of a major platform vendor's security association implies technical review of the integration, which is not the same as an attestation of the company's own controls.

CC on FDA and Regulatory StatusNo device claim is made and the product is scoped accordingly. Most administrative and operational products sit here and are not penalised for it, because this axis grades the appropriateness of the positioning rather than possession of a clearance.
Third Party Estimated

No device authorisation applies to the security platform itself, and there is a boundary here that this index has not previously recorded.

The devices being protected are regulated. A cleared medical device is authorised in a specific configuration, and manufacturers commonly constrain what may be changed on it. A security product that patches, segments or quarantines such a device is acting on a regulated object, and the practical questions are whether patching affects the device's cleared status and who carries responsibility if containment interrupts a clinical function.

The surrounding regime has also tightened: manufacturers now face explicit cybersecurity obligations at submission, which shifts some of this burden upstream over time but does nothing for the installed base of legacy devices that is the whole reason this category exists.

DD on AI Governance and Bias DisclosureNothing published on how model behaviour is governed or tested. Multilingual operation with no subgroup performance sits here when the vendor markets recognition quality as a strength, because a caller the system failed to understand leaves no complaint and no record.
Vendor Published

Nothing published on evaluation, monitoring or error handling.

The failure mode specific to this product is a false positive with clinical consequences. If behavioural anomaly detection misreads an unusual but legitimate pattern, the response is to isolate a device, and the devices most likely to behave unusually are the oldest and least standard ones, which are disproportionately found in the hospitals with the least money to replace them. A detection system tuned on modern estates will generate more false alarms in exactly the settings least able to absorb the disruption.

Nothing published addresses detection performance across device age, manufacturer or hospital size, and no monitoring or appeal process for an automated containment is described.

DD on AI Liability and RecourseNothing published on what happens when the system is wrong.
Vendor Published

Two passes located no detection rate, no false positive rate, no validation methodology for device classification and no warranty, indemnity or remediation commitment. The classification gap is the one that matters most here because errors do not stay where they are made.

Device identification feeds the risk score, and the risk score feeds the segmentation policy built on top of it, so a device typed wrongly at the first step produces a wrong risk rating and then a wrong network policy, and each stage inherits the error while looking like an independent judgement. The failure directions are both consequential and neither is countable from anything published.

A clinical device wrongly typed as low risk and segmented permissively is an opening nobody is looking at. A device wrongly typed as high risk and segmented tightly can lose the connectivity it needs to function, and in a clinical setting that is a patient safety event arising from a security control.

Nothing describes how classification is validated, what proportion of devices are typed by inference rather than by a definitive identifier, or what a hospital sees about the confidence of a given classification. Ask for classification accuracy by device class, the false positive rate on anomaly detection, and what the vendor commits to when a segmentation policy breaks a clinical device.

Integration and Deployment
CC on EHR and Interoperability DepthIntegration is claimed through standards or a middleware layer with no system named and nothing to verify.
Vendor Published

The record system is not the integration target and the grade reflects that rather than penalising it. What matters here is the security and biomedical estate: the platform integrates with a major cloud security operations product, belongs to that vendor's security association, and is designed to slot into a managed security provider's stack.

The biomedical engineering connection is the one that would matter most to a hospital and is least described. A device inventory that does not reconcile with the biomedical asset register produces two conflicting sources of truth about the same equipment, and nothing published addresses that reconciliation.

CC on Deployment Model and Data ResidencyA single hosted option with location implied rather than committed.
Third Party Estimated

Not described in detail. The product observes network traffic passively, which implies sensors or taps inside the hospital estate rather than an agent on each device, and that is the correct architecture given that agents cannot be installed on most clinical equipment.

What is not published is where analysis happens, what leaves the site, or how long captured data is retained. For a system inspecting clinical network traffic those are the first questions and they are unanswered.

Commercial
DD on Commercial TransparencyNothing a buyer can establish before a sales conversation. A published pricing claim contradicted by evidence also grades here.
Third Party Estimated

Nothing published: no price, no mechanism, no unit of sale.

The natural unit in this category is the connected device or the bed, and the difference matters because device counts per bed vary enormously between a community hospital and an academic centre. Independent commentary positions this product as a good fit for smaller health systems, under 500 beds, which makes the absence of a published entry price more consequential: those are precisely the buyers least able to run a long procurement to discover it. Ask for the per device or per bed rate, and establish separately what changed commercially after the acquisition, including whether the product can still be bought standalone.

BB on Setting and Specialty CoverageCoverage is named with validation behind part of it.
Third Party Estimated

Purpose built for one setting and complete within it. The scope is the hospital estate rather than the enterprise generally, covering information technology, operational technology, general connected devices and connected medical devices in a single inventory, which is the combination that distinguishes healthcare from other environments.

It is specialty agnostic by nature, since the estate spans every department, and independent commentary identifies smaller health systems as a particular fit, which is a useful counterweight in a category whose largest vendors orient to the biggest academic centres. Held at B because coverage is the provider estate only, with nothing addressing manufacturers, payers or the wider supply chain, and the healthcare only focus that is its strength also bounds it.

Commercial

Pricing

Vendor-published figures are labeled as such. Figures labeled “Estimated” are derived from third-party sources and have not been confirmed by the vendor.

Entry Price Pricing Basis BAA Tier Implementation Source
Not published. Sold directly and through managed security service providers. Not located. The July 2025 acquisition raises a specific question: whether the agreement now sits with the acquiring platform, what changed in it, and whether data collected under the original arrangement is reachable by the wider business. Not published. Deployment is passive and observes network traffic rather than installing agents on clinical devices, which is the only workable approach for equipment that cannot be modified. Third Party Estimated

Nothing is published: no price, no mechanism, no unit of sale. The natural unit in this category is the connected device or the staffed bed, and the difference is large because device counts per bed vary enormously between a community hospital and an academic medical centre.

That absence is more consequential here than for most vendors, because independent commentary positions this product as a particular fit for smaller health systems under 500 beds, and those are precisely the buyers with the least capacity to run a long procurement simply to discover a starting price. Establish the per device or per bed rate, and whether passive sensors are priced separately from the software.

Then establish what changed commercially after the July 2025 acquisition: whether the product can still be bought standalone, whether it is being bundled into the acquirer's broader asset platform, and what happens to a multi year agreement if the healthcare specific modules are folded into a general product. That last question is the same one this index raised about another security vendor in this lane facing acquisition, and it belongs in the contract rather than in a reassurance.